Meters



        SOCOMEC METER SELECTION CHART


                            Single phase  Single phase       Three phase         Three phase  Three phase
         Network - Input Current  Direct Connect, 40A  Direct Connect, 80A  Direct Connect, 80A  Direct Connect, 100A CT Connect, 1/5A






         Active Energy Meters:   E00  E03  E11  E13   E17    E21   E23    E27    E30   E33    E41   E43    E47
         COUNTIS E
         Part No.           48503058 48503039 48503060 48503043 48503047 48503062 48503050 48503054 48503005 48503012  48503063 48503065 48503056
         Main Specifications
         RS485 Modbus RTU   -      •     -      •     -      -     •      -      -     •      -     •      -

         Ethernet Modbus TCP/RTU -  -    -      -     •      -     -      •      -     -      -     -      •
         Width (17.5mm)     1 Module  1 Module  2 Modules 2 Modules 2 Modules 4 Modules 4 Modules 4 Modules 7 Modules 7 Modules 4 Modules 4 Modules 4 Modules
         Functions
         Total/Partial energy (kWh)  •/•  •/•  •/•  •/•  •/•  •/•  •/•    •/•    •     •      •/•   •/•    •/•
         Active power (kW)  •      •     •      •     •      •     •      •      •     •      •     •      •
         Reactive power (kvar)  •  •     •      •     •      •     •      •      -     via COM  •   •      •

                                                                                       Up to 4      Up to 4   Up to 4
         Tariff for kWh     -      Dual  Dual   Dual  Dual   Dual  Dual   Dual   -            Dual
                                                                                       via COM      via COM  via COM
         Total/Partial energy (kvarh) •/•  •/•  •/•  •/•  •/•  •   •/•    •/•    -     via COM  •/•  •/•   •/•
         Apparent energy (kVA)  -  via COM  -   •     •      •     •      •      -     via COM  •   •      •
         Load curve         -      -     -      -     -      -     -      -      -     via COM  -   via COM  via COM
         Measurement (I, V, P, Q, S, F   •  •  •  •   •      •     •      •      -     via COM  •   •      •
         and PF)
         CT connection indication  -  -  -      -     -      -     -      -      -     -      •     •      •
         Bi-directional (energy                                                  -
         consumption and    •      •     •      •     •      •     •      •            •      •     •      •
         production)
         Integrated web server  -  -     -      -     •      -     -      •      -     -      -     -      •
         Compatibility with   -    •     -      •     •      -     •      •      -     •      -     •      •
         WEBVIEW
         Accuracy

         Active energy (IEC 62053-21) Class 1  Class 1  Class 1  Class 1  Class 1  Class 1  Class 1  Class 1  Class 1  Class 1  Class 1  Class 1  Class 1
         Reactive energy    Class 2  Class 2  Class 2  Class 2  Class 2  Class 2  Class 2  Class 2  -  -  Class 2  Class 2  Class 2
         (IEC 62053-23)
         Characteristics
         Metrological LED   •      •     •      •     •      •     •      •      •     •      •     •      •
         Pulse output/Alarm  100 Wh  100 Wh  100 Wh  100 Wh  -  100 Wh  100 Wh  100 Wh  -  -  Config.  Config.  Config.
         Phase/Neutral inversion   -  -  -      -     -      -     -      -      •     •      -     -      •
         protection












         304                                     1300 556 601  |  ipd.com.au  |  V17-R05
   299   300   301   302   303   304   305   306   307   308   309