Moulded Case Circuit Breakers (MCCB)



        SACE Tmax XT MOULDED CASE CIRCUIT BREAKERS


         Thermal Magnetic Trip Unit
           -  Current threshold and rotary switch for short
            circuit and overload protection                                                                         1
           -  Used in both AC and DC networks

         Electronic Trip Units (DIP, TOUCH)
           -  Dip switches allow manual setting when the trip
            unit is off
           -  On/Off LED indication
           -  LED – test and signaling of the most recent trip
           -  Thermal memory function
           -  External neutral
           -  Modbus RTU com (XT2 and XT4)
           -  Used in AC network
           -  High reliability and tripping precision


         Packages
         DEFAULT FUNCTIONALITIES AND UPGRADEABLITY OF THE TRIP UNITS.



                        Standard  Standard  Measuring  Voltage  Frequency Power  Adaptive  Data  Network  Advanced  ROCOF  Power
                        Protection  Measures  Package  Protections Protections Protections Protections Logger  Analyzer  Voltage  Protections Controller
                                                                                          Protections
         Ekip Touch        ●      ●       ↑      ↑      ↑       ↑      ↑      ↑      ↑       ↑      ↑      ↑
         Ekip Touch Measuring  ●  ●       ●      ↑      ↑       ↑      ↑      ↑      ↑       ↑      ↑      ↑
         Ekip Hi-Touch     ●      ●       ●      ●      ●       ↑      ●      ●       ●      ↑      ↑      ↑
         ● Available by default                ↑ Upgradeable                ↑ Some functions available. Upgradeable with the full package.

         Measurement Functions

                                                                                      Ekip Touch   Ekip
         Instantaneous Measurements                                      Ekip Touch   Measuring    Hi-Touch
         Currents (RMS)                         L1, L2, L3, Ne        [A]  ●           ●            ●
         Ground Fault Current (RMS)             Ig                    [A]  ●           ●            ●
         Measuring package                                                             ●            ●
         Phase-Phase voltage (RMS)              U12, U23, U31         [V]  ●           ●            ●
         Phase-Neutral voltage (RMS)            U1, U2, U3            [V]  ●           ●            ●
         Phase Sequence                                                   ●            ●            ●
         Frequency                              f                    [Hz]  ●           ●            ●
         Active Power                           P1, P2, P3, Ptot     [kW]  ●           ●            ●
         Reactive Power                         Q1, Q2, Q3, Qtot    [kVAR]  ●          ●            ●
         Apparent Power                         S1, S2, S3, Stot    [KVA]  ●           ●            ●
         Power Factor                           PF1, PF2, PF3, PF total   ●            ●            ●
         Peak Factor                            Total                     ●            ●            ●
         Counters: Recorded from Installation or from the Last Reset
                                                Ep + Eq Total,      [kWh]
         Active + Reactive Energy               Ep + Eq Positive,  [kVARh]  ●          ●            ●
                                                Ep + Eq Negative   [KVAh]
                                                                    [kWh]
         Apparent Energy                        Es Total           [kVARh]  ●          ●            ●
                                                                   [KVAh]
         ●  Available as standard
         ●  Available as software package to be ordered. Contact IPD