Variable Speed Drives



        ABB HVAC DRIVES


        Software Characteristics for the ACH580 HVAC Drives Family

        The ACH580 drives come with a range of advanced features that not only provide a thorough heating, ventilation and air conditioning control, but also
        make drive integration, commissioning, and operation easier than ever before


                Soft start and stop                                   Fireman’s override
                User defined ramps for softer fan/pump/compressor starts   In case of fire emergency, drives run fans ignoring faults
                and stops eliminate mechanical and electrical stresses on   and warnings, to ensure safe evacuation and mitigate the
                the system.                                           spread of smoke.

                Flying start
                                                                      Active braking
                The feature allows to catch free-wheeling fans and
                                                                      In case of fire emergency, drives run fans ignoring faults
                smoothly accelerate or decelerate them to a required
                                                                      and warnings, to ensure safe evacuation and mitigate the
                speed, without wasting time on braking.
                                                                      spread of smoke.
                Air filter monitoring
                                                                      Intelligent pump control
                The drive alarms on a clogged filter, to maintain air quality
                                                                      The feature maintains stable pumping process for up to 8
                and avoid energy losses.
                                                                      pumps operating in parallel. It is possible to optimise the
                                                                      speed and number of pumps for creating required flow
                Leakage monitoring                                    and pressure, even if one or more pumps fail.  4
                In closed loop HVAC systems, drives can alarm on the
                leakage in the system, preventing flooding and property
                                                                      Bearing monitoring
                damage.
                                                                      Bearings are one of the weakest points in HVAC
                                                                      applications. Drives can alarm on the bearing upcoming
                Resonance monitoring
                                                                      failure, so it could be replaced timely, without HVAC
                Mechanical aspect of resonance damages the application
                                                                      process interruption.
                itself and connected piping/ductwork, while acoustic
                aspect makes the environment noisy. ABB drives skip
                                                                      Motor heating
                resonance frequencies for better comfort and longer
                                                                      The feature prevents condensation and saves the motor
                equipment lifetime.
                                                                      from failure due to corrosion, which is typical for rooftop
                                                                      mounted air handlers.
                System overpressure protection
                The interlock protects water pipes/air ducts by stopping
                pump/fan operation when the measured pressure exceeds   Pump dry run protection
                a threshold, e.g. due to closed valves/dampers.       The interlock stops operation when the pressure on the
                                                                      pump suction side is below a threshold, to prevent pump
                                                                      damage from running dry.

                                                                      Frost protection
                                                                      Cold temperatures outside might lead to heating coil
                                                                      freezing. To avoid damage, drives can alarm on a too low
                                                                      air temperature and shut down the system.

                                                                      Sleep/boost
                                                                      The feature stops the pump at low demand, instead of
                                                                      running it slowly below its efficient operating range. Allows
                                                                      to save energy and extend the pump and motor lifetime by
                                                                      decreasing start/stop cycles during the day.