Page 9 - Blitzductor_XT
P. 9
®
BLITZDUCTOR XT selection guide according to interface / signal
The right arrester for every interface and signal:
Use our online selection tool to find the right arrester for the applications and signal circuits to be protected:
www.dehn-international.com/en/search-interface-yellowline
Interface Four-pole Two-pole Interface Four-pole Two-pole
Signal module module Signal module module
0-20 mA, 4-20 mA (also with HART)) 920 324 920 224 LUXMATE bus 920 344 920 244 •
24 V DC systems with earthed 920 314 LUXMATE bus 920 344 920 244 •
negative pole
M-bus 920 345 920 245 •
4-20 mA (also with HART) according 920 344 920 244 •
to NAMUR recommendation NE 21 or MODBUS 920 371 920 271 •
EN 61000-4-5, open-circuit voltage Modem M1 920 322 920 222
1 kV line-PG
a/b lines 920 347 • MPI Bus 920 371 920 271 •
ADVANT 920 370 920 270 N1 LAN 920 371 920 271
920 370 920 270
ADSL 920 347 920 247
N2 Bus 920 371 920 271
ADSL 2+ 920 347 (Johnson Controls, LON, FTT 10)
Binary signals 920 320 – 327 920 220 – 225 Optocoupler interface 920 364
Bitbus 920 370 920 270 Procontic CS31 (RS 232) 920 322
BLN 920 342 920 242 Procontic T200 (RS 422) 920 371 •
920 345 920 245
PROFIBUS-DP/FMS 920 371 920 271
CAN bus (data line only) 920 371 920 271 •
PROFIBUS-PA 920 344 920 244 •
C-bus (Honeywell) 920 371 920 271 •
PROFIBUS-PA Ex (i) 920 381 920 538
DALI bus 920 244
PROFIBUS SIMATIC NET 920 371 920 271 •
Data Highway Plus 920 342 920 242 •
PSM-EG-RS 422 920 371 •
Datex-P 920 375
PSM-EG-RS 485 920 371 920 271 •
Delta Net Peer Bus 920 370 920 270
Rackbus (RS 485) 920 371 920 271 •
Device Net (data line only) 920 371 920 271 •
R-bus 920 340 920 240 •
DMX 920 371
RS 485 920 371 920 271 •
DSL 920 347 920 247
RS 422, V11 920 371 920 271 •
Dupline 920 243 •
S-bus 920 370 920 270
E1 920 375
SafetyBUS p 920 371 920 271 •
E-Bus (Honeywell) 920 345 920 245 •
SDLC 920 370 920 270
EIB 920 310 920 211
Securilan-LON-BUS 920 340 920 240
Electro-acoustic systems (ELA) 920 347
SDSL 920 375 •
ET 200 920 370 920 270
SHDSL 920 375 920 211 •
Ex (i) measuring circuits 920 381 920 280
SIGMASYS 920 345 920 245
Fieldbus Foundation 920 344 920 244 • 920 325 920 225
Fieldbus Foundation Ex (i) 920 381 920 538 SINEC L1 920 370 920 270
FIPIO/FIPWAY 920 344 920 244 SINEC L2 920 370 920 270
FIP I/O 920 370 920 270 SS97 SINIS (RS 232) 920 322 920 222
FSK 920 371 920 271 • SUCONET 920 371 920 271 •
Genius I/O bus 920 342 920 242 Telephones, system telephones, 920 347 920 247 •
e.g., Siemens, HICOM, Alcatel
HDSL 920 375
Temperature measurement PT 100, 920 322 920 222
IEC bus (RS 485) 920 371 920 271 • PT 1000, Ni 1000, NTC, PTC
INTERBUS-INLINE (I/O) 920 345 • Temperature measurement Ex (i) 920 384
Interbus INLINE Fernbus 920 371 920 271 • Telecommunications systems 920 347 920 247 •
K-bus 920 344 920 244 TTL 920 322 920 222 •
KBR-Energiebus 920 370 920 270 TTY 920 364
KNX-bus 920 310 920 211 920 362
ISDN S 0 920 375 • TTY 4-20 mA 920 324 920 224
ISDN S / U 2m 920 375 • Universal lightning equipotential bonding 920 310 920 211
2m
ISDN U / U 920 347 920 247 • V 24 (RS 232 C) 920 322
K0 P0
LON TP/XF 78 920 340 920 240 VDSL 920 310 920 211
TP/FTT 10 up to 1 A and TP/LPT10 920 345 920 245 Video (two-wire) 920 371 920 271 •
TP/FTT 10 920 371 920 271
BLITZDUCTOR XTU with actiVsense technology:
®
®
The actiVsense technology automatically detects the operating voltage and optimally adapts the voltage protection level to this voltage.
The interfaces marked with this symbol are protected by BLITZDUCTOR XTU with actiVsense technology. 9