Page 43 - Contactors_Catalogue
P. 43
ABB MOTOR CONTROL AND PROTECTION FOR ROLLING STOCK APPLICATIONS 2/19
—
Main accessories with screw terminals
MS132-(K)B, MS165-B, MO132-B, MO165-B
02
Manual motor starters can be equipped with auxiliary contacts for lateral/front mounting, signal-
ing contacts for lateral mounting, undervoltage releases and shunt trips. Two different signaling
contacts are available. The accessories can be fitted wiring free and without tools. A variety of
combinations is possible as required for the application. The auxiliary contacts change position
with the main contacts. The signaling contact SK signals tripping regardless if it was caused by
HKF1-11 short-circuit or overload. The signaling contact CK signals tripping in case it was caused by short-
circuit.
Undervoltage releases are used for remote tripping of the manual motor starters especially
for emergency stop circuits. Shunt trips release the MMS used for remote tripping. These main
accessories are suitable throughout the MS132-(K)B/MS165-B/MO132-B/MO165-B ranges.
Suitable for Auxiliary Auxiliary Description Type Order code Pkg Weight
contacts contacts qty (1 pce)
1SBC101209F0014 pce kg
N.O.
N.C.
MS132-(K)B,
1
1
HK1-11 Auxiliary contacts – mountable on the front HKF1-11 1SAM201901R1001 10 0.015
MS165-B, 1 0 HKF1-10 1SAM201901R1003 10 0.013
MO132-B, 0 1 HKF1-01 1SAM201901R1004 10 0.013
MO165-B
2 0 HKF1-20 1SAM201901R1002 10 0.015
Auxiliary contacts – mountable on the right
MS132-(K)B, 1 1 max. 2 pieces HK1-11 1SAM201902R1001 2 0.035
MS165-B, 2 0 max. 2 pieces HK1-20 1SAM201902R1002 2 0.035
1SBC101210F0014 MO165-B 0 2 2 0 max. 2 pieces HK1-02 1SAM201902R1003 2 2 0.035
MO132-B,
0.035
HK1-20L
with lead contacts
1SAM201902R1004
SK1-11 Signaling contacts – mountable on the right SK1-11 1SAM201903R1001 2 0.035
1
1
for tripped alarm,
MS132-(K)B,
MS165-B, max. 2 pieces
MO132-B, 2 0 for tripped alarm, SK1-20 1SAM201903R1002 2 0.035
MO165-B max. 2 pieces
0 2 for tripped alarm, SK1-02 1SAM201903R1003 2 0.035
max. 2 pieces 1SAM301901R1001 2 0.035
1
for short-circuit alarm, CK1-11
MS132-(K)B,
1
1SBC101286F0014 MS165-B 2 0 max. 2 pieces 1SAM301901R1002 2 0.035
for short-circuit alarm, CK1-20
max. 2 pieces
0 2 for short-circuit alarm, CK1-02 1SAM301901R1003 2 0.035
CK1-11 max. 2 pieces
42.1 1.66" 1.77" 45 2.83" 72 3.54" 90
9 0.35" 5.5 0.22" 27.8 1.09"
42.3 1.67"
68.8 2.71"
73.1 2.9"
SK1
42.1 1.66" 1.77" 45 2.83" 72 3.54" 90
9 0.35" 5.5 0.22" 27.8 1.09"
42.3 1.67" 2CDC242001F0012
68.8 2.71"
HK1 2CDC131100C0201 - Rev. A
Main dimensions mm, inches