Page 1124 - Din prodcuts 2020
P. 1124

11/18            ELECTRICAL INSTALL ATION SOLUTIONS FOR BUILDINGS   2CHC 420 001 C0201




          —
          carat®
          Movement detectors / comfort switches




          Product    Article-No.    Order-No.       Pack/Qty  Product     Article-No.    Order-No.       Pack/Qty


                     Busch-Watchdog relay mechanism                       Busch-Watchdog extension insert  ) 1
                     3 wire connection (neutral conductor required).      3 wire connection (neutral conductor required).
                     For Busch-Watchdog 180 flush-mounted Sensor          For extending Busch-Watchdog 180 flush-mounted and
                     Standard 6810-21x-101.                               Busch-Watchdog Presence tech installations.
                     For Busch-Watchdog 180 flush-mounted sensor          For combination with relay insert 6401 U-102 and
                     Comfort II 6800-xxx-104 and 6800-xxx-104M.           6402 U.
                     For Busch-Watchdog Presence tech 6813-xxx-101 und    For combination with MOS-Fet insert 6804 U-101.
                     6813/11-xxx.                                         For combination with Dimmer insert 6593 U and
                     Rated voltage: 230 V, +10 % / -10 %                  6550 U-101.
                     Rated frequency: 50 Hz                               For Busch-Watchdog 180 flush-mounted sensor
                     Outputs: 1x Normally open contact, potential-bound   Comfort II 6800-xxx-104 and 6800-xxx-104M.
                     Suitable for: 230 V incandescent lamps, 230 V halogen   For Busch-Watchdog Presence tech 6813-xxx-101 und
                     lamps, fluorescent lamps and low-voltage halogen     6813/11-xxx.
                     lamps, that are operated via transformers.           Rated voltage: 230 V~, +10 % / -10 %
                     Rated power: 700 W/VA                                Rated frequency: 50 Hz
                                                                          Control/Signal outputs: 1, electronic output, potential-
                     Temperature range (Device): 0 °C to 55 °CBritish     bound
                     Standard EN 60669-2-1                                Temperature range (Device): 0 °C to 35 °C
                                                                          6805 U-500     2CKA006800A2161  1/10
                     6812 U-101-500  2CKA006800A2160  1/10    Mounting     35 mm deep flush 1gang
                                                              boxes:      or Dual Box 3070-2/35 BSDB.
                     Busch-Watchdog MOS-Fet Insert  )  )  )  )  )  )  Cover frames:   1gang frame 1721 BS-2xG
                                               4
                                             2
                                           1
                                              3
                                                 5
                                                  6
                     2-wire connection (neutral conductor not required)   or Dual Box frame 1722 BSDB-2xG.
                     For Busch-Watchdog 180 flush-mounted Sensor   2gang product    2gang combination with adapter plate
                     Standard 6810-21x-101.                   combinations:  APBS in Dual Box only.
  11
                     For Busch-Watchdog 180 flush-mounted sensor
                                                              1)  Not combinable with relay switch insert 6812 U-101.
                     Comfort II 6800-xxx-104 and 6800-xxx-104M.
                     For Busch-Watchdog Presence tech 6813-xxx-101 und
                     6813/11-xxx.                                         Busch-Watchdog 180 flush-mounted comfort
                     Combinable with Busch-Watchdog extension insert      sensor II  )
                                                                                1
                     6805 U.                                              with select-lens
                     Operation also possible via conventional push buttons   For automatic switching of devices dependent on
                     (2020 US, 2021/6 UK).                                motion and brightness.
                     Rated voltage: 230 V~, +10 % / -10 %                 For relay inserts 6401 U-102, 6402 U and 6812 U-101.
                     Rated frequency: 50 Hz                               For MOS-Fet insert 6804 U-101.
                     Suitable for: 230 V incandescent lamps, 230 V halogen   For Dimmer insert 6593 U.
                     lamps and low-voltage halogen lamps with conventional   For extension insert 6805 U.
                     transformers or Busch Electronic Transformer.        With integrated selector switch for ON-AUTOMATIC-OFF
                     Rated power: 60 - 420 W/VA                           (lockable).
                                                                          Soft phase-out: In combination with the 6593 U (mode
                     Temperature range (Device): 0 °C to 35 °CBritish     of operation: Soft OFF) the illumination is dimmed
                     Standard EN 60669-2-1                                down within 60 sec and switched off.
                                                                          Surveillance density: 18 sectors with 72 switching
                                                                          segments.
                     6804 U-101-500  2CKA006800A2219  1/10
                                                                          Switch-off delay: 10 sec to 30 min or short-time pulse
          1)  In case of electronic transformers, 5 % transformer losses.  1 sec adjustable.
          2)  In the case of conventional transformers, take ~20% transformer loss into account.  Detection range: frontal: 12 m, lateral: 8 m
          3)  Not suitable for the activation of energy-saving lamps, conventional and electronic
          ballast units and LED lamps.                                    Detection angle: 180 °
          4)  Not suitable for activating the staircase time delay.       Brightness limit value: 5 Lux Up to daytime operation
          5)  Cannot be used to control relais.                           Mounting height: 0.8 m - 1.2 m
          6)  Requires an NIS international socket, E-No. 372507676.      Protection class (Sensor): IP 20
                                                                          Temperature range (Device): 0 °C to 35 °C
                                                              anthracite  6800-81-104    2CKA006800A2268  1
                                                              ivory white  6800-82-104   2CKA006800A2099  1/10
                                                              studio white  6800-84-104  2CKA006800A2101  1/10
                                                              1)  Please order the respective flush-mounted insert separately.