Page 1350 - Din prodcuts 2020
P. 1350
11/244 ELECTRICAL INSTALL ATION SOLUTIONS FOR BUILDINGS 2CHC 420 001 C0201
—
future® linear
Socket outlets
Product Article-No. Order-No. Pack/Qty Product Article-No. Order-No. Pack/Qty
Busch-Object socket outlet ) Buschmat® FI - Insert ) 1
1
shuttered with earth leakage breaker with connecting conductor
With screwless terminals. Protection of downstream consumers.
DP (2 P + E) Rated fault current: 30 mA.
Incl. Cover plate with extract mechanism. DP cut off (P,N)
Rated voltage: 250 V~ Without claw fixation.
Rated current: 16 A Rated frequency: 45-60 Hz.
Protection class (Device): IP 20 Rated voltage: 230 V~
Rated current: 16 A
anthracite 20 EUAB-81 2CKA002013A5404 10
Protection class (Device): IP 20
ivory white 20 EUAB-82 2CKA002013A5405 10 Temperature range (Device): -25 °C to 40 °C
aluminium 20 EUAB-83 2CKA002013A5406 10 anthracite 3151 UC-81 2CKA003117A0009 1/10
silver )
2
ivory white 3151 UC-82 2CKA003117A0005 1/10
studio white 20 EUAB-84 2CKA002013A5407 10
aluminium 3151 UC-83 2CKA003117A0010 1/10
studio white, 20 EUAB-884 2CKA002013A5409 10 silver ) 2
matt )
2
studio white 3151 UC-84 2CKA003117A0006 1/10
2
black matt ) 20 EUAB-885 2CKA002013A5410 10
studio white, 3151 UC-884 2CKA003117A0012 1/10
1) Increased shock protection . matt ) 2
2) Surface painted.
black matt ) 2 3151 UC-885 2CKA003117A0013 1/10
1) Protective measure according to VDE 0100; can be proven or checked using the
2
3
FI-SCHUKOMAT, SCHUKO® socket outlet (RCD) ) ) ) Profitest 0100S testing device, for example.
1
with earth leakage circuit breaker 2) Surface painted.
Shuttered.
DP cut off (P,N)
Without PE monitoring. SCHUKO® socket outlet
11
With connecting conductor and protection of with hinged lid
downstream socket outlets. With screwless terminals.
Rated fault current: 30 mA. DP (2 P + E)
With fixing claws. Hinged lid notches when opened.
Rated frequency: 45-60 Hz. Rated voltage: 250 V~
Rated voltage: 230 V~ Rated current: 16 A
Rated current: 16 A Protection class (Device): IP 20
Protection class (Device): IP 20 anthracite 20 EUK-81 2CKA002018A1486 10
Temperature range (Device): -25 °C to 40 °C
ivory white 20 EUK-82 2CKA002018A1465 10
anthracite 3120 EUCB-81 2CKA003116A0667 1/10
aluminium 20 EUK-83 2CKA002018A1487 10
ivory white 3120 EUCB-82 2CKA003116A0661 1 silver ) 1
aluminium 3120 EUCB-83 2CKA003116A0668 1/10 studio white 20 EUK-84-500 2CKA002018A1509 10/100
silver )
4
studio white, 20 EUK-884 2CKA002018A1494 10
studio white 3120 EUCB-84 2CKA003116A0662 1 matt ) 1
studio white, 3120 EUCB-884 2CKA003116A0670 1/10 black matt ) 1 20 EUK-885 2CKA002018A1495 10
matt )
4
1) Surface painted.
black matt ) 3120 EUCB-885 2CKA003116A0671 1/10
4
1) Connecting terminals approved in accordance with VDE 0620-1 as connectors.
2) Protective measure according to VDE 0100; can be proven or checked using the
Profitest 0100S testing device, for example.
3) Increased shock protection .
4) Surface painted.