Page 379 - Din prodcuts 2020
P. 379

4/25




          —
          Motor operating and autoreclosing devices for
          MCBs, RCDs and Switch Disconnectors



                                                                                                                       4
                                    Motor operating devices
                                                                     DS2C-CM
                                    Supply                      V    12 ... 30 V a.c. +10% - 15% (50-60Hz); 12 ... 48 V d.c. +10% -
                                                                     15%
                                    Insulation voltage          V    2500 for 1 minute
                                    Power          12 V a.c.    VA   < 15
                                    consumption    24 V a.c.    VA   < 22
                                    during the
                                    operation      30 V a.c.    VA   < 25
                                                   12 ... 48 V d.c.  VA  < 20
                                    Power consumption at rest   VA   < 1.5
                                    Remote control *                 by means of dry contacts
                                    Make-time at ambient temperature  sec  < 1
                                    Opening time at ambient temperature  sec  < 0.5
                                    Time before attempting to reclose the  sec  8
                                    motor operator
                                    Number of operations             < 20.000
                                    Operating temperature       °C   - 25 ... + 55
                                    Storage temperature         °C   - 40 ... + 70
                                    Mounting                         on DIN rail EN 60715 by means of fast clip device
                                    Protection degree (EN 60529)     terminals: IP2X
                                                                     enclosure: IP4X
                                    Cables length of control circuit  m  < 1500
                                    Cables cross-section        mm 2  < 2.5
                                    Signal contact (terminals 3 – 4 – 5)   1NO + 1NC (change-over contact)
                                    Current carrying capacity        5 A (250 V AC) (resistive load)
                                    Auxiliary contact (terminals 6 – 7 – 8)  1NO + 1NC (change-over contact)
                                    Current carrying capacity        3 A (250 V AC) (resistive load)
                                    Remote control terminals         Terminal 9 = make contact; Terminal 10 = opening contact
                                                                     Terminal 11 = common reference for control contacts, +5 V
                                                                     d.c. (supplied by the motor operating device)
                                    * Note: In case of the device opening due to a fault, please wait 8 seconds before attempting to reclose the motor operator.
                                    Motor operating devices
                                    Function: S2C-CM, F2C-CM and DS2C-CM allow the remote control (opening or closing)
                                    of the coupled device. Suitable for S200 series MCBs, SD200 switch disconnectors,
                                    F200 RCCBs, RCBOs DS201, DS201 (2019), DS202C.

                                    Description             Bbn     Order details            Price  Weight Pack
                                                            8012542                          1 piece 1 piece unit

                                                            EAN     Type code  Order code           kg    pc.
                                    Motor operating device for 1P   026259  S2C-CM1  2CSS201997R0013  0.166  1
                                    S200 series MCBs and SD200
                                    switch disconnectors
                                    Motor operating device for 2P   026358  S2C-CM2/3  2CSS203997R0013  0.166  1
                                    and 3P S200 series MCBs ,
                                    2P DS201 (2019) RCBOs and
                                    SD200 switch disconnectors
                                    Motor operating device for 4P   026457  S2C-CM4  2CSS204997R0013  0.166  1
                                    S200P MCBs
                                    Motor operating device for 2P   026556  F2C-CM  2CSF200997R0013  0.166  1
                                    and 4P F200 RCCBs
                                    Motor operating device for 1P+N   135951  DS2C-CM  2CSR201997R0013  0.166  1
                                    and 2P DS201, DS202C RCBOs
                                    Motor operating device for F200   020721  F2-125A-  2CSF200997R1214                     0,36  1
                                    125A RCCB                       24V-CM4
                                    Motor operating device for F200   600626  F2-125A-  2CSF200997R1205            0,36  1
                                    125A RCCB                       230V-CM4