Page 790 - Din prodcuts 2020
P. 790

8/50             ELECTRICAL INSTALL ATION SOLUTIONS FOR BUILDINGS   2CHC 420 001 C0201




          —
          Energy efficiency
          Sensors and Accessories




                           Open-core sensors                           Maximum secure insertion of wiring cables is
                           The open-core sensors are able to measure all   guaranteed by this sensors solution.
                           types of current, whether AC, DC or mixed, up
                           to 80 A in TRMS, enabling exact and effective   Everything is built into an 18 or 25 mm wide unit
         Open-core sensors  measurements. As each sensor is equipped   to enable precise and effective measurements.
         Installation manual  with its own microprocessor for processing the   This makes these CMS sensors the most compact
                           signal, the measurement data is transmitted   and most powerful
                           digitally to the Control Unit via bus interface,   on the market.
                           maximizing data reliability. Disturbances
                           like those experienced with analog data     Depending on the application, solid-core sensors
                           now most definitely belong to the past.     are chosen between up to four
                                                                       different mounting options to making this
                           With this solution a faster cabling is      solution as flexible as possible.
  8
                           guaranteed, since wiring cables are directly
                           inserted in the sensors without the aid of   The solid-core units feature an enclosed structure
                           a screwdriver. No special tools are needed   and AC measurement accuracy*
                           for the entire connection process.          of ≤ ± 0.5 %, and are therefore suitable for all
                                                                       applications in which maximum-precision
                           With AC accuracy* of ≤ ±1.0 %, they can be   measurement is crucial.
                           used in a multitude of applications without any
                           problem: System pro M, DIN rail and Cable tie.  *  All accuracy specifications refer to the rel-
                                                                        evant full-scale value and apply to 25 °C.
                           Thanks to their U shape, the open-core      Accessories
         Solid-core sensors  sensors can be retrofitted to existing    The Control Unit of the circuit monitoring system
         Installation manual  installations, without the need to discon¬nect   need a flat cable for receive branches
                           the cabling or shut down the equipment,     measurements from sensors. The flat cable
                           being the key for brownfield extension.
                                                                       should be a 4-pin cable, flexible in length. Flat
                                                                       cable are available in several lengths in order to
                           Solid-core sensors
                           Alternating (AC), direct (DC) or mixed (TRMS)   cover the most kind of application. Cables with
                                                                       the greater length are designed with the purpose
                           currents – the CMS sensors monitor          of being adapted, through cutting,
                           and measure all types of current over       to the various lengths required by the
                           a measurement range of up to 160 A (TRMS).   applications.
                           They even measure harmonic components in the
                           signal curve. The measurements are digitally
                           transmitted through bus interface, enabling
                           reliability of data and removing disturbance
                           effects.
   785   786   787   788   789   790   791   792   793   794   795