          SMISSLINE TP plug-in system
          RCCBs F400 series, A      y   type




                                    F402 A type
                                    Function: protection against the effects of sinusoidal alternating and direct pulsating earth
                                    fault currents; protection against indirect contacts and additional protection against direct
                                    (with IΔn = 30 mA) contacts.
                                    Application: residential, commercial, industrial.
                                    Standard: IEC/EN 61008
                                    Marking: according to EN 61008

           F402                     Number Rated  Rated  Bbn     Order details             Price  Weight  Pack
                                    of poles residual current  801254                      1 piece  1 piece  unit
                                           current
                                           IDn mA  In A  EAN     Type code   Order code           kg      pc.
                                    2        10   25     2037033  F402 A 25/0.01  2CSF502110R0250  0.250  1
                                             30   25     2034339  F402 A 25/0.03  2CSF502110R1250  0.250  1
                                             30   40     2036937  F402 A 40/0.03  2CSF502110R1400  0.250  1
                                           100    40     2034230  F402 A 40/0.1  2CSF502110R2400  0.250   1
                                                                                                                       9
                                    F404 A type
                                    Function: protection against the effects of sinusoidal alternating and direct pulsating earth
                                    fault currents; protection against indirect contacts and additional protection against direct
           F404                     (with IΔn = 30 mA) contacts. Product helpful where for installation habits, for wiring with
                                      busbars or cables, for special needs neutral on the left is needed.
                                    Application: residential, commercial, industrial.
                                    Standard: IEC/EN 61008
                                    Marking: according to EN 61008

                                    Number Rated  Rated  Bbn     Order details             Price  Weight  Pack
                                    of poles residual current  761227                      1 piece  1 piece  unit
                                           current
                                           IDn mA  In A  EAN     Type code   Order code           kg      pc.
                                    2        30   25     0104253  F404 A 25/0.03  2CCF544110E0250  0.430  1
                                             30   40     0104260  F404 A 40/0.03  2CCF544110E0400  0.430  1
                                           100    40     0104277  F404 A 40/0.1  2CCF544120E0400  0.430   1
                                           300    40     0104284  F404 A 40/0.3  2CCF544130E0400  0.430   1
                                             30   63     0104291  F404 A 63/0.03  2CCF544110E0630  0.430  1
                                           100    63     0104307  F404 A 63/0.1  2CCF544120E0630  0.430   1
                                           300    63     0104314  F404 A 63/0.3  2CCF544130E0630  0.430   1

                                    F404 A type 16 /  Hz
                                                2
                                                  3
                                    Function: protection against the effects of sinusoidal alternating and direct pulsating earth
                                    fault currents; protection against indirect contacts and additional protection against direct
                                    (with IΔn = 30 mA) contacts.
                                                  2
                                    The RCCB F200 16 /  Hz can work at rated frequency of 16 /  Hz which is common in
                                                                                  2
                                                                                    3
                                                    3
                                    railways applications
                                    Application: railways
                                    Standard: IEC/ EN 61008
                                    Marking: according to EN 61008
                                    Number Rated  Rated  Bbn     Order details              Price  Weight  Pack
                                    of poles residual current  761227                       1 piece  1 piece  unit
                                           current
                                           IDn mA  In A  EAN     Type code    Order code           kg     pc.
                                    4        30   63     0104376  F404 A-LF 63/0.03 2CCF544110E0631  0.430  1
                                           300    63     0104383  F404 A-LF 63/0.3  2CCF544130E0631  0.430  1