Page 854 - Din prodcuts 2020
P. 854
9/24 ELECTRICAL INSTALL ATION SOLUTIONS FOR BUILDINGS 2CHC 420 001 C0201
—
SMISSLINE TP plug-in system
RCCBs F400 series, A K y type
F402 A K type, short-time delayed
Function: protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents, providing the best compromise between safety and continuity in the service
thanks to the resistance to unwanted trippings; protection against indirect contacts and
additional protection against direct (IΔn = 30 mA) contacts.
Application: residential, commercial, industrial.
Standard: IEC/EN 61008
Surge current resistance (wave 8/20) = 3000 A
Marking: according to EN 61008
F402
Number Rated Rated Bbn Order details Price Weight Pack
of poles residual current 761227 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
2 30 40 0104482 F402 A-K 2CCF552310E0400 0.250 1
40/0.03
9
F404 A K type, short-time delayed
Function: protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents, providing the best compromise between safety and continuity in the service
thanks to the resistance to unwanted trippings; protection against indirect contacts and
additional protection against direct (IΔn = 30 mA) contacts.
Application: residential, commercial, industrial.
Standard: IEC/EN 61008
FS 404 K and S Surge current resistance (wave 8/20) = 3000 A
Marking: according to EN 61008
Number Rated Rated Bbn Order details Price Weight Pack
of poles residual current 761227 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
4 30 40 0104321 F404 A-K 40/0.03 2CCF544310E0400 0.430 1
100 40 0104338 F404 A-K 40/0.1 2CCF544320E0400 0.430 1
30 63 0104345 F404 A-K 63/0.03 2CCF544310E0630 0.430 1
F404 A selective type
Function: protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents with an intentional tripping delay, which permits to realize the selectivity with
downstream instantaneous devices (for more information about selectivity see the technical
guide); protection against indirect contacts.
Application: commercial, industrial.
Standard: IEC/EN 61008
Surge current resistance (wave 8/20)=5000 A
Marking: according to EN 61008
Number Rated Rated Bbn Order details Price Weight Pack
of poles residual current 761227 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
4 100 63 0104352 F404 A-S 63/0.1 2CCF544220E0630 0.430 1
300 63 0104369 F404 A-S 63/0.3 2CCF544230E0630 0.430 1