Ordering information, IEC
OTDC M-Series 315…1000A
Robust DC switch-disconnector for up to 1500V DC applications. The new design has a more compact size,
higher efficiency and higher performance. The two-pole 1500V DC design that reduces switch power losses
up to 50%. The physical footprint is up to 80% smaller than other solutions in the market. Handles and shafts
are not included.
— Rated operational 05
OTDC315_800_F_11 current [A] Number Single package
Voltage [V DC] DC-21B DC-PV2 of circuits Circuit 1) Number of poles Type 2) Order code
Front operated, mechanism between the poles
1000 315 315 1 2a, 2b 2 OTDC315F11 1SCA158172R1001
1000 400 400 1 2a, 2b 2 OTDC400F11 1SCA158196R1001
1000 500 500 1 2a, 2b 2 OTDC500F11 1SCA158220R1001
1000 630 500 1 2a, 2b 2 OTDC630F11 1SCA158244R1001
1000 800 500 1 2a, 2b 2 OTDC800F11 1SCA158853R1001
1000 630 630 1 6c, 6g 4 OTDC630F22-PV2 1SCA161682R1001
1000 800 800 1 6c, 6g 4 OTDC800F22-PV2 1SCA161684R1001
1000 800 - 1 6c, 6g 4 OTDC800F22 1SCA160619R1001
1000 1000 - 1 6c, 6g 4 OTDC1000F22 1SCA161286R1001
1000 315 315 2 4a, 4c 4 OTDC315F22 1SCA158294R1001
1000 400 400 2 4a, 4c 4 OTDC400F22 1SCA158298R1001
1000 500 500 2 4a, 4c 4 OTDC500F22 1SCA158302R1001
1000 630 500 2 4a, 4c 4 OTDC630F22 1SCA158306R1001
1000 315 - 3 7a, 7e 6 OTDC315F33 1SCA158286R1001
1000 400 - 3 7a, 7e 6 OTDC400F33 1SCA158287R1001
1000 500 - 3 7a, 7e 6 OTDC500F33 1SCA158288R1001
1500 315 315 1 2a, 2b 2 OTDC315FV11 1SCA158178R1001
1500 400 400 1 2a, 2b 2 OTDC400FV11 1SCA158202R1001
1500 500 500 1 2a, 2b 2 OTDC500FV11 1SCA158226R1001
1500 630 500 1 2a, 2b 2 OTDC630FV11 1SCA158250R1001
1500 800 500 1 2a, 2b 2 OTDC800FV11 1SCA158856R1001
1500 630 630 1 6c, 6g 4 OTDC630FV22-PV2 1SCA161683R1001
1500 800 800 1 6c, 6g 4 OTDC800FV22-PV2 1SCA161685R1001
1500 800 - 1 6c, 6g 4 OTDC800FV22 1SCA161280R1001
1500 1000 - 1 6c, 6g 4 OTDC1000FV22 1SCA161288R1001
1500 315 315 2 4a, 4c 4 OTDC315FV22 1SCA158295R1001
1500 400 400 2 4a, 4c 4 OTDC400FV22 1SCA158299R1001
1500 500 500 2 4a, 4c 4 OTDC500FV22 1SCA158303R1001
1500 630 500 2 4a, 4c 4 OTDC630FV22 1SCA158307R1001
1500 315 - 3 7a, 7e 6 OTDC315FV33 1SCA158844R1001
1500 400 - 3 7a, 7e 6 OTDC400FV33 1SCA158847R1001
1500 500 - 3 7a, 7e 6 OTDC500FV33 1SCA158850R1001
Side operated, mechanism at the end of the switch
1000 315 315 1 2a, 2b 2 OTDC315F02S 1SCA160644R1001
1000 400 400 1 2a, 2b 2 OTDC400F02S 1SCA161230R1001
1000 500 500 1 2a, 2b 2 OTDC500F02S 1SCA161235R1001
1000 630 500 1 2a, 2b 2 OTDC630F02S 1SCA161266R1001
1500 315 315 1 2a, 2b 2 OTDC315FV02S 1SCA161226R1001
1500 400 400 1 2a, 2b 2 OTDC400FV02S 1SCA161232R1001
1500 500 500 1 2a, 2b 2 OTDC500FV02S 1SCA161237R1001
1500 630 500 1 2a, 2b 2 OTDC630FV02S 1SCA161268R1001
1) Circuit connection 6c, 6g – connection bar kit OTDCKIT800FS11 included with the package – installation mandatory.
Please see floating circuit in page 46 and the grounded circuits in pages 56-57. Single circuit 1a and Double circuit 3 with connection bar kit accessories.
2) Phase barriers are included to pole configurations _22/_33/_02 – installation mandatory. You can find the accessories starting from page 47 and dimensional
drawings starting from page 61.