Page 44 - OTDC Switch
P. 44
44 SWITCH-DISCONNECTORS OTDC AND OTDCP
—
Ordering information, UL
OTDC M-Series 250…1000A
Robust DC switch-disconnector for up to 1500V DC applications. The new design has a more compact size,
higher efficiency and performance. The two-pole 1500V DC design that reduces switch power losses up to
50%. The physical footprint is up to 80% smaller than other solutions in the market. Handles and shafts are
not included.
— Rated operational
OTDC 250...600UF_11 current [A] Single package
Number of Number of
Voltage [V DC] UL98B IEC60947-3 circuits Circuit 1) poles Type 2) Order code
Front operated, mechanism between the poles
1000 250 315 1 2a, 2b 2 OTDC250UF11 1SCA158160R1001
1000 320 400 1 2a, 2b 2 OTDC320UF11 1SCA158184R1001
1000 400 500 1 2a, 2b 2 OTDC400UF11 1SCA158209R1001
1000 600 630 1 2a, 2b 2 OTDC600UF11 1SCA158233R1001
1000 800 800 1 6c, 6g 4 OTDC800UF22 1SCA161282R1001
1000 1000 1000 1 6c, 6g 4 OTDC1000UF22 1SCA161290R1001
1000 250 315 2 4a, 4c 4 OTDC250UF22 1SCA158292R1001
1000 320 400 2 4a, 4c 4 OTDC320UF22 1SCA158296R1001
1000 400 500 2 4a, 4c 4 OTDC400UF22 1SCA158300R1001
1000 600 630 2 4a, 4c 4 OTDC600UF22 1SCA158304R1001
1500 250 315 1 2a, 2b 2 OTDC250UFV11 1SCA158166R1001
1500 320 400 1 2a, 2b 2 OTDC320UFV11 1SCA158190R1001
1500 400 500 1 2a, 2b 2 OTDC400UFV11 1SCA158215R1001
1500 600 630 1 2a, 2b 2 OTDC600UFV11 1SCA158239R1001
1500 800 800 1 6c, 6g 4 OTDC800UFV22 1SCA161284R1001
1500 1000 1000 1 6c, 6g 4 OTDC1000UFV22 1SCA161292R1001
1500 250 315 2 4a, 4c 4 OTDC250UFV22 1SCA158293R1001
1500 320 400 2 4a, 4c 4 OTDC320UFV22 1SCA158297R1001
1500 400 500 2 4a, 4c 4 OTDC400UFV22 1SCA158301R1001
1500 600 630 2 4a, 4c 4 OTDC600UFV22 1SCA158305R1001
Side operated, mechanism at the end of the switch
1000 250 315 1 2a, 2b 2 OTDC250UF02S 1SCA161224R1001
1000 320 400 1 2a, 2b 2 OTDC320UF02S 1SCA161228R1001
1000 400 500 1 2a, 2b 2 OTDC400UF02S 1SCA161234R1001
1000 600 630 1 2a, 2b 2 OTDC600UF02S 1SCA161258R1001
1500 250 315 1 2a, 2b 2 OTDC250UFV02S 1SCA161243R1001
1500 320 400 1 2a, 2b 2 OTDC320UFV02S 1SCA161249R1001
1500 400 500 1 2a, 2b 2 OTDC400UFV02S 1SCA161256R1001
1500 600 630 1 2a, 2b 2 OTDC600UFV02S 1SCA161264R1001
1) Circuit connection 6c, 6g – connection bar kit OTDCKIT800FS11 included with the package – installation mandatory.
Please see floating circuit in page 46 and the grounded circuits in pages 56-57. Single circuit 1a and Double circuit 3 with connection bar kit
accessories.
2) Phase barriers are included to pole configurations _22/_02 – installation mandatory.
You can find the accessories starting from page 47 and dimensional drawings starting from page 61.