Page 105 - Sace Emax 2 Catalogue
P. 105

ACCESSORIES                                                                       6/3



          —

          Standard supply













                           The fixed versions of SACE Emax 2 automatic cir-  The withdrawable versions of automatic circuit-
                           cuit-breakers and switch-disconnectors are al-  breakers and switch-disconnectors are always sup-
                           ways supplied as standard with the following ac-  plied as standard with the following accessories:
                           cessories:                                  •  closed circuit-breaker racked-out mechanism lock
                           •  IP30 protection for switchgear door      •  lifting plates for E2.2 ... E2.6 circuit-breakers
                           •  lifting plates for E2.2 … E6.2 circuit-breaker  •  lever for racking in and racking out
                           •  front terminals for E1.2 circuit-breaker  •  anti-insertion lock.
                           •  adjustable rear terminals for E2.2 … E6.2 cir-
                            cuit-breaker, mounted in HR – HR configuration.   In addition, for withdrawable automatic circuit-
                                                                       breakers only:
                           In addition, for fixed automatic circuit-breakers   •  four standard open/closed auxiliary contacts -
                           only:                                        AUX 4Q 400V
                           •  four standard open/closed auxiliary contacts -   •  four terminals for auxiliary connections
                            AUX 4Q 400V                                •  mechanical signalling of the tripping of the pro-
                           •  four terminals for auxiliary connections  tection trip unit - TU Reset
                           •  mechanical signalling of the tripping of the pro-  •  contact signalling tripping of Ekip protection
                            tection trip unit - TU Reset                trip unit S51 250V.
                           •  contact signalling tripping of Ekip protection
                            trip unit S51 250V.                        The fixed parts feature:                        06
                                                                       •  IP30 protection for switchgear door
                                                                       •  anti-insertion lock
                                                                       •  standard shutter lock – SL
                                                                       •  adjustable rear terminals, mounted in HR – HR
                                                                        configuration.