6/4              SACE EMAX 2 LOW VOLTAGE AIR CIRCUIT-BREAKERS



          —

          Accessories for circuit-breakers






                           SACE Emax 2 circuit-breakers offer a wide range   tion and installation requirements of every cus-
                           of accessories developed to satisfy the applica-  tomer.

                                                                   Automatic     Switch-      Derived versions
                                                                   circuit-breaker  disconnector
                                                                   E1.2   E2.2 -   E1.2  E2.2 -   CS  MT  MTP
                                                                          E4.2 -        E4.2 -   E2.2 - E4.2 - E6.2
                                                                          E6.2          E6.2
          Signalling
          Standard open/closed auxiliary contacts - AUX 4Q           /      /      /      /   -     -
          Open/closed auxiliary contacts - AUX 6Q                  -        /    -        /   -     -
          Open/closed auxiliary contacts- AUX 15Q                    /      /      /      /   -     -
          Auxiliary position contacts - AUP
          Ready to close signalling contact - RTC                    /      /      /      /   -     -     -
          TU Reset mechanical signalling of the tripping of protection trip unit - TU Reset    /    /   -  -  -  -  -
          Contact signalling tripping of Ekip protection trip unit - S51    /    /   -  -     -     -     -
          Second contact signalling tripping of Ekip protection trip unit - S51/2  -   /   -  -  -  -     -
          Contact signalling loaded springs – S33 M/2 (supplied with Motor)   /    /    /    /   -  -
          Control
          Opening and closing release - YO/YC                        /      /      /      /   -     -         *
          Second opening and closing release - YO2/YC2               /      /      /      /   -     -     -
          Undervoltage release - YU                                  /      /      /      /   -     -     -
          Electronic time-delay device for undervoltage release - UVD   /    /     /      /   -     -     -
          Motor - M                                                  /      /      /      /   -     -
          Remote reset - YR                                          /      /    -      -     -     -     -
          Opening and closing release test unit - YO/YC Test Unit    /      /      /      /   -     -       *
          Safety
          Key lock and padlock in open position - KLC and PLC        /      /      /      /   -     -
          Key lock and padlock in racked-in / test / racked-out position - KLP and PLP
          Shutter lock - SL
          Lock for racking-out mechanism with circuit-breaker in closed position
          Lock for racking in / racking out the mobile part when the door is open - DLR   -  -  -   -
          Lock to prevent door opening when circuit-breaker is in racked-in /
          test position - DLP                                      -             -
          Lock to prevent door opening when circuit-breaker is in closed position - DLC    /    /    /    /   -  -
          Anti-insertion lock                                        /      /      /     /
          Mechanical operation counter - MOC                         /      /      /      /   -     -
          Protection devices
          Protection device for opening and closing pushbuttons - PBC    /    /    /      /   -     -
          IP30 Protection                                            /      /      /     /    -     -
          IP54 Protection                                            /      /      /      /   -     -
          Terminal covers - HTC / LTC                                /    -      -      -     -     -     -
          Separators - PB                                            /      /      /      /   -     -     -
          Connections
          Orientable rear terminal - HR/VR                           /      /      /       /   -    -
          Front terminal - F                                                /             /   -     -
          Other configurations                                       /      /      /      /   -     -
          Interlocks and switching devices
                                                                     /    /    /    /    /    /    /    /
          Mechanical interlock - MI                                                           -     -     -
          Automatic transfer switches - ATS                          /      /      /      /   -     -     -
                Standard accessory for fixed circuit-breaker      Standard accessory for fixed part
                Accessory on request for fixed circuit-breaker     Accessory on request for fixed part
              Standard accessory for mobile part         *      Only closing release YC
             Accessory on request for mobile part