Page 220 - Sace Emax 2 Manual for design engineers
P. 220

ABB | SACE Emax 2
                 Information in menu The following information will be available in the About-Modules menu if Ekip Touch has detected the module
                                    correctly:
                                     Information    Description
                                     SN and version  Identifier and SW version of the module
                                                    Address of the module, assigned to the module by a DHCP server at the time of
                                                    connection to the network in the case of configuration with a dynamic IP, or can be
                                     IP address     set via the menu in the event of a static IP.
                                                        NOTE: without a DHCP server, the module automatically adopts a random IP
                                                        address within the 169.254.xxx.xxx range
                                                    Subnet mask; identifies the method for recognizing the subnet to which the modules
                                     Network Mask
                                                    belong and enables modules to be searched for within a defined set of recipients.
                                                    IP address of the node to which the module is connected, in the presence of several
                                     Gateway address
                                                    subnets
                                                    Address assigned by ABB, with OUI (Organizationally Unique Identifier) equal to
                                     MAC address
                                                    ac:d3:64, which uniquely identifies the manufacturer of an Ethernet device



              Remote configurations Additional parameters can be accessed via the service connector (via Ekip Connect) or via a system bus
                                    communication:
                                     Parameter    Description                                         Default
                                                  Allows the CRL (Certificate Revocation List) to be used to ascertain
                                     CRL Enable
                                                  whether the server certificate is valid
                                     Clock update
                                     hardening    Enables control of the time reference transmitted by the SNTP server
                                     enable
                                     SNTP Server   Enables the position of the SNTP server to be set in relation to the
                                     Location     network in which the module is installed
                                     SNTP Time zone Defines the time zone to be used for synchronism  +00:00
                                     SNTP Daylight   Used to select whether daylight saving time is present (ON) or not   OFF
                                     Saving Time  (OFF) in the country to which the synchronization time refers
                                                  Permits (Enabled ARP) the periodic generation of a Gratuituos ARP
                                     Disable      message, used by Ekip Connect to rapidly find the modules via   ARP Enabled
                                     Gratuitous ARP
                                                  Ethernet scan without knowing the IP address beforehand










































       218 | © 2020 ABB |  1SDH001330R1002 - ECN000134959 - Rev. A                   External electronic accessories | 10 - Ekip Com Hub
   215   216   217   218   219   220   221   222   223   224   225