Page 51 - SACE Tmax XT - Catalogue
P. 51

PROTECTION TRIP UNITS                                                             3/17



















                                                                                                                       03
                        Maximum flexibility is guaranteed for customers:
                        on the XT5, XT7 and XT7 M, with Ekip Touch trip
                        units, the interchangeable rating plug enables the
                        rated current to be changed according to system
                        requirements.











 Rated uninterrupted
 current ranges [A]  XT1  XT2  XT3  XT4  XT5               XT6                 XT7                 XT7 M
 Power Distribution Protection
 Thermal-magnetic
 TMD  16…160  (1)  1,6…32  63…250  16…32
 TMA  40…160     40…250              320…630             630...800
 Ekip Dip
 Ekip Dip LS/I    10…160  40…250     250…630             630…1000            630…1600            630…1600
 Ekip Dip LIG  10…160  40…250        250…630             630…1000            630…1600            630…1600
 Ekip Dip LSI    10…160  40…250      250…630             630…1000            630…1600            630…1600
 Ekip Dip LSIG    10…160  40…250     250…630             630…1000            630…1600            630…1600
 Ekip Touch
 Ekip Touch LSI  40…160  100…250     250…630                                 630…1600            630…1600
 Ekip Touch LSIG  40…160  100…250    250…630                                 630…1600            630…1600
 Ekip Touch Measuring LSI  40…160  100…250  250…630                          630…1600            630…1600
 Ekip Touch Measuring LSIG  40…160  100…250  250…630                         630…1600            630…1600
 Ekip Hi-Touch LSI  40…160  100…250  250…630                                 630…1600            630…1600
 Ekip Hi-Touch LSIG  40…160  100…250  250…630                                630…1600            630…1600
 Motor Protection
 Magnetic
 MF/MA     1…160  100…200  10…200    320…500
 Ekip Dip
 Ekip M Dip I    10…160  40…250      250…630             630…1000            630…1600            630…1600
 Ekip M Dip LIU    25…160  40…160    250…500             630...800
 Ekip Touch
 Ekip M Touch LRIU  40…100  100…200  250…500                                 630…1600            630…1600
 Generator Protection
 Thermal-magnetic
 TMG  16…160  63…250                 320…630
 Ekip Dip
 Ekip G Dip LS/I    25…160  40…250   250…630             630…1000            630…1600            630…1600
 Ekip Touch
 Ekip G Touch LSIG                   250…630                                 630…1600            630…1600
 Ekip G Hi-Touch  LSIG               250…630                                 630…1600            630…1600
 1) 16A and 20A for N, S, H have the TMF trip unit