Page 302 - V16 Catalogue Final
P. 302

METER SELECTION CHART - NMI/SUB-BILLING





                                                   Single phase           Three phase            Three phase
          Network - Input current                Direct connect, 63A    Direct connect, 100A     CT connect, 5A


          Energy and Sub-billing meters


          References                                 IPD163C               IPD3100C               IPD3005C
          Main specifications
          Complies with the requirements of NMI
          and is certified for trade use (billing app.)                    Approved
          Self powered                                 •                      -                      -
          Width (18mm)                              2 Module               7 Module               7 Module
          Real-time Measurements
          Uln/Ull per phase and Average                •                      •                      •
          Current per phase and Average, In            •                      •                      •
          kW/kvar/kVA per phase and Total              •                      •                      •
          PF per phase and Total                       •                      •                      •
          Frequency                                    •                      •                      •
          Demands and Peak Demands                     •                      •                      •

          Energy Measurements (per phase and 3-phase total)
          Active energy kWh; Imp, Exp, Net, Total      •                      •                      •
          Reactive energy kvarh Imp, Exp, Net, Total   •                      •                      •
          Apparent energy kVAh Total                   •                      •                      •
          4-Quadrant kvarh                             -                      •                      •
          TOU Energy (4 Tariffs)                       -                      •                      •

          Power Quality
          Voltage and Current Unbalance                •                      •                      •
          THD, THOD, THED, K-Factor, Crest-Factor, TDD  -                     •                      •
          Individual Harmonics (2nd to 31st)           -                      •                      •

          Logging
          Max./Min. & Peak Demand Recording            -                      •                      •
          12 Monthly Energy Log                        -                      •                      •
          SOE Log                                      -                      •                      •
          Data Recorder Log with 2MB Memory            -                      •                      •
          Inputs and Outputs
          DI                                           -                      3                      3
          Energy Pulse Output (Solid State Relay)      1                      1                      1
          Metrological LED Energy Pulse Output         1                      1                      1
          Communications
          RS-485 MODBUS RTU                            •                      •                      •

          Real-time Clock
          Battery-backed real-time clock @ 6ppm        -                      •                      •
          Clock error ≤ 0.5s/day                       -                      •                      •
          Can be set through front panel or communication  -                  •                      •
          System Integration
          Easy intergration in to other Automation or SCADA   -               •                      •
          systems
          Accuracy
          Active energy (IEC 62053-21)                 1                      1              0.5s (Acc.to IEC62053 22)
          Reactive energy (according to IEC 62053-23)  2                      2                      2


    294   V16-PM-R04                                    www.ipd.com.au                             Phone: 1300 556 601