Page 306 - V16 Catalogue Final
P. 306

MULTIFUNCTION METERS




          Features:                            DIRIS A-10
          - Accuracy class 0.5S to IEC62053-22.
          - Integrated temperature sensor.      Description                                          Part No.
          - Detects wiring errors.              DIRIS A-10 multifunction meter with pulse output     48250400
          - Suitable for LV installations.      DIRIS A-10 multifunction meter with RS485 Modbus     48250401
          - DIN rail mount: 4 modules wide.     communication and pulse output
          - Large backlit LCD display.          Auxiliary supply: 110-277V AC
          - Webview remote access software.     Total harmonic distortion up to row 51.
          - Two-rate tariff function.
          - Standard IEC 61557-12.             - Available in light grey on request.






                                               STANDARD FUNCTIONS
                                                Connection
                                                  CT .../5A

                                                Metering
                                                  Active energy: +/- kWh.
                                                  Reactive energy: + / - kvarh.
                                                  Hours.
                        DIRIS A-10              Instantaneous RMS Values
                                                  Current (3I, In).
                                                  Voltage & frequency instanceous: 3V, 3U, F
                                                  Active, reactive and apparent power, per phase and total (±3P, ±3Q, 3S, ±∑P, ±∑Q, ∑S) .
                                                  Power factor, per phase and total (3PF, ∑PF).

                                                Maximum Values
                                                  Current (3I, In).

                                                Power Quality Measurements
                                                  Harmonic distortion rate on current and voltage integrated up to 51st  harmonic (THD 3I, 3V, 3U).

                                                1 Pulse Output
                                                  Pulse configurable (type, weight, time) in kWh, or kvarh or monitoring 3I, In,3V, 3U, F, ∑P, ∑Q, ∑S,
                                                  ∑PF, THD 3I, 3V, 3U or command through RS485 (48250401 only).

                                                Energy Measurement Precision
                                                  Class 0.5s - IEC 62053-22 (Active energy).
                                                  Class 2 - IEC 62053-23 (Reactive energy).
                                               - For current transformers (CT’s) refer to pages 325-331.






                                               - For CT shorting link terminals refer to page 322 & 549.


















    298   V16-PM-R04                                    www.ipd.com.au                             Phone: 1300 556 601
   301   302   303   304   305   306   307   308   309   310   311