Page 309 - V16 Catalogue Final
P. 309

MULTIFUNCTION METERS




        Features:                            DIRIS A40 MULTIFUNCTION MONITORING DEVICE
        - Accuracy to IEC 61557-12.          CLICK 'N' CONNECT CURRENT SENSORS
              Class 0.5 (Meter + TE/TF/iTR sensors).                                                               POWER
              Class 1 (Meter + TR sensors).   PLUG & PLAY WITH AUTOMATIC DETECTION OF CT RATIOS                  MONITORING
        - Meter accuracy Class 0.2.           Description                                        Part No.
        - Panel Mount; 98 x 98mm.
        - RJ12 CT Connection.                 Diris A-40 multi-function meter with RS485 Modbus  48250500
        - Single circuit metering & measurement - 3CT inputs.  110/400V AC or 120/300V DC auxiliary supply.
        - Integrated webserver with Webview-S software
          (48250501 only).                    Diris A-40 multi-function meter with Ethernet Modbus TCP   48250501
        - Assisted Configuration.             and webserver - RS485 Modbus
                                              110/400V AC or 120/300V DC auxiliary supply.

                                              Diris A-40 multi-function meter with Profibus DPV1 - RS485 Modbus  48250502
                                              110/400V AC or 120/300V DC auxiliary supply.

                        +
                                             DIRIS A-40 FUNCTIONS
                                                                                                 A-40
            48250501         Integrated webserver
                                              Multi-measurement
                                              currents, voltages (ph / ph and ph / n)            •
                                              active / reactive / apparent powers, power factor, frequency  •
                                              Power factor, cos ϕ,tan ϕ                          •
                                              Voltage/current unbalance                          •
                                              Metering
                                              kWh (+ /-), kvarh (+ /-), kVAh                     •
                                              Multi-tariff (max 8)                               •
                                              hour meter                                         •
                                              Quality analysis
                                              Total harmonic distortion THDv, THDu, THDi         •
                                              Individual harmonics V, U & I (up to rank 63)      •
                                              Voltage dips, cut-offs and surges (EN50160)        •
                                              overcurrents                                       •
                                              Alarms                                             •
                                              Communication
                                              RS485 Modbus as standard                           •
                                              Ethernet Modbus                                    • (only on 48250501)
                                              PROFIBUS DPV1                                      • (only on 48250502)

                                              3 Digital inputs / 2 logical outputs               •
                                              BACnet IP                                          • (only on 48250501)

                                              Webserver with remote access software              • (only on 48250501)





















                     Various types of current sensors can be connected to the DIRIS A-40 refer page 313.




        Phone: 1300 556 601                            www.ipd.com.au                                  V16-PM-R04  301
   304   305   306   307   308   309   310   311   312   313   314