Page 50 - V16 Catalogue Final
P. 50

SACE TMAX XT MOULDED CASE CIRCUIT BREAKERS
           MOULDED CASE CIRCUIT BREAKER SELECTION


             Model      Frame Size  Thermal magnetic     Electronic          kA Rating          Rating (A)

                           XT1      TMD from 25A to 160A                      36kA              Up to 160A
                           XT3      TMD 200A & 250A      -                                      200A & 250A


                                    TMD up to 32A
                           XT2                           LS/I up to 160A      36kA & 70kA       Up to 160A
                                    TMA from 50A to 160A


                                    TMD up to 32A
                           XT4                           LS/I up to 250A      36kA & 70kA       Up to 250A
                                    TMA from 50A to 160A



                           XT5      TMA 400A & 630A      LS/I 400A & 630A     36kA & 70kA       400A & 630A




                           XT6      TMA 800A             LSI 800A             50kA & 70kA       800A




                           XT7      -                    LSI for 1000A to 1600A  50kA & 70kA    1000A to 1600A




                          XT7M      -                    LSI for 800A to 1600A  50kA & 70kA     800A to 1600A


          Contact IPD for other options.


          TRIPPING CHARACTERISTICS
                                           t[s]
                                                          Long time
                                           1000           pickup ( L)

                                                          Long time
                                                          delay
                                            100



                                                                 Short time
                                             10                  pickup ( S)
                                           Time in seconds  1.0  Short time delay

                                                               (I t ON)
                                                                2


                                                                      Instantaneous
                                            0.1                       pickup ( I)
                                                     Ground fault
                                                      (G)
                                           0.01
                                          0.005
                                               0.5 1           10         100   xln
                                                         Multiples of rated current


     42   V16-PD-MCCB-R04                               www.ipd.com.au                             Phone: 1300 556 601
   45   46   47   48   49   50   51   52   53   54   55