        POWER PROTECTION - SURGE DIVERTERS


                                 TYPE 1+2 - WITH MEN LINK
                                 PARALLEL REDUNDANCY MULTIMOV
        Features:                Imax             Iimp                                                              1
           - All mode protection  (8/20μs)   In (8/20μs)   (10/350μs)   Connection  MCOV    Voltage Protection   Alarm   Part No.
           - Active alarms       (kA)     (kA)    (kA)     Type     AC (V)  Level - Up (kV)  Contact
           - Parallel redundant   MSB
          arrangement
           - Percentage active display  100  40   12.5     1+0      275    < 1.5           Yes    SD1-100-275
           - Safe metal enclosure  150    60      19       1+0      275    < 1.6           Yes    SD1-150-275
           - Standards IEC 61643-11,   200  80    25       1+0      275    < 1.7           Yes    SD1-200-275
          AS/NZS 1768            100      40      12.5     3+0      275    < 1.5           Yes    SD3-100-275
                                 150      60      19       3+0      275    < 1.6           Yes    SD3-150-275
                                 200      80      25       3+0      275    < 1.7           Yes    SD3-200-275








                SD1-100-275
                                 TYPE 1+2 - WITHOUT MEN LINK
                                 PARALLEL REDUNDANCY MULTIMOV
        Features:                Imax             Iimp
           - All mode protection  (8/20μs)   In (8/20μs)   (10/350μs)   Connection  MCOV    Voltage Protection   Alarm   Part No.
           - Parallel redundant   (kA)    (kA)    (kA)     Type     AC (V)  Level - Up (kV)  Contact
          arrangement
           - LED status active display  MSB
           - Safe metal enclosure  100    40      12.5     3+1      275    < 1.4           Yes    SDN3-100-275
           - Standards IEC 61643-11,    150  60   18.75    3+1      275    < 1.45          Yes    SDN3-150-275
          AS/NZS 1768            200      80      25       3+1      275    < 1.5           Yes    SDN3-200-275











               SDN3-100-275
                                 TYPE 1+2 - WITHOUT MEN LINK
                                 COMBINED SPARK GAP/MOV
        Features:                Imax             Iimp
           - Hybrid spark gap design spark   (8/20μs)   In (8/20μs)   (10/350μs)   Connection  MCOV    Voltage Protection   Alarm   Part No.
          gap & MOV in series    (kA)     (kA)    (kA)     Type     AC (V)  Level - Up (kV)  Contact
           - LED status          MSB
           - Active alarm standard
           - Safe metal enclosure  250    100     50 (N-PE)  3+1    480    < 1.4           Yes    HSG3-250-480-N
           - Standards IEC 61643-11,
          AS/NZS 1768











              HSG3-250-480-N




                                               1300 556 601  |  ipd.com.au  |  V17-R04                       235