Power Supplies & Transformers



        AC UPS AMPLON FAMILY - RT SERIES


                                                 1 - 3kVA 1 PHASE MAINTENANCE BYPASS SWITCH
        Features:                                             Maximum
           - Voltage 220/230/240V AC              Maximum Input   Output Power  Connections   Dimensions (mm)  Part No.
           - Mounts at the rear of the UPS or on the rack  Current (A)  (kVA)  (kW)   W x H x D
           - Operating temperature 0°C to 40°C
                                                  For Single UPS Application
                                                                         Input -
                                                                         IEC C14
                                                  10          1    0.9                270 x 88 x 75  PDB1211A230035
                                                                         Output -
                                                                         IEC C13 x 6
                                                                         Input -
                       PDB1211A230035                                    IEC C20
                                                  16          3    2.7   Output -     270 x 88 x 75  PDB1211A231035
                                                                         IEC C13 x 6,
                                                                         IEC C19 x 1
                                                 5/6/8/10kVA 1 PHASE MAINTENANCE BYPASS SWITCH
        Features:                                             Maximum
           - Voltage 200/208/220/230/240V AC      Maximum Input   Output Power   Connections   Dimensions (mm)  Part No.
           - Mounted at the rear of the UPS or in the rack  Current (A)  (kVA)  (kW)  W x H x D
           - Operating temperature 0°C to 55°C
          (When operating temperature 40 to 55°C, Bypass   For Single UPS Application
          switch will be de-rated 75% of its capacity)                   Input -
                                                                         Terminal Block
                                                  63          10   10    Output -     440 x 88 x 120  PDB1511A531035
                                                                                                              (1)
                                                                         Terminal Block x 1,
                                                                         C13 x 3, C19 x 2
                                                  For Parallel UPS Application
                                                                         Input -
                                                                         Terminal Block
                                                  125         20   20                 440 x 130 x 120  PDB1512A511035 (2)
                                                                         Output -
                       PDB1512A511035                                    Terminal Block x 1
                                                 (1)  Cable 8AWG/6mm² Cu (5/6kVA) & 6AWG/10mm² Cu (8/10kVA)
                                                 (2)  Cable 4AWG/16mm² Cu (10/12kVA) & 35mm² (16/20kVA)














                                                 1 - 3KVA EXTERNAL BATTERY PACK 2RU
                                                  Power   Battery           Dimensions (mm)  Weight   Part No.
                                                  (VA)                      W x H x D      (kg)
                                                          Includes 2 Strings of                    BBU022B2009035
                                                  1000                      440 x 88 x 335  15.2
                                                          2 x 12V/9Ah                              BBU022B2009035-M(*)
                                                          Includes 2 strings of                    BBU042B5009035
                                                  2000                      440 x 88 X 430  27.4
                                                          4 x 12V/9Ah                              BBU042B5009035-M(*)
                                                          Includes 2 strings of                    BBU062B6009035
                       BBU022B109535              3000    6 x 12V/9Ah       440 x 88 x 610  39     BBU062B6009035-M(*)
                                                 -  Rack/Tower Installation
                                                 (*)  Shorter lead time item
                                                 1 - 3KVA EMPTY EXTERNAL BATTERY PACKS

                                                                            Dimensions (mm)
                                                  Power (VA)                                       Part No.
                                                                            W x H x D
                                                  Empty External Battery Pack RT PRO-1KB           UPSRT102A00EB-0
                                                  Empty External Battery Pack RT PRO-2KB  440 x 88 x 610  UPSRT202A00EB-0
                                                  Empty External Battery Pack RT PRO-3KB           UPSRT302A00EB-0


         240                                     1300 556 601  |  ipd.com.au  |  V17-R12