5/58             ABB  MOTOR PROTECTION AND CONTROL

          —
          AS09..S ... AS16..S and

          ASL09..S ... ASL16..S  3-pole contactors - with spring terminals
          Technical data


          Main pole - Utilization characteristics according to IEC
          Contactor types             AC operated AS09..S           AS12..S               AS16..S
                                      DC operated ASL09..S          ASL12..S              ASL16..S
          Standards                           IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
          Rated operational voltage Ue max.   690 V
          Rated frequency (without derating)  50 / 60 Hz
          Conventional free-air thermal current Ith
          acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C  20 A   22 A                  22 A
            With conductor cross-sectional area  2.5 mm²            2.5 mm²               2.5 mm²
          AC-1 Utilization category
          For air temperature close to contactor
            Ie / Rated operational current AC-1  θ ≤ 40 °C 20 A     22 A                  22 A
   05
            Ue max. ≤ 690 V, 50/60 Hz   θ ≤ 60 °C 15 A              17 A                  17 A
                                        θ ≤ 70 °C 12 A              14 A                  14 A
            With conductor cross-sectional area  2.5 mm²
          AC-3 Utilization category
          For air temperature close to contactor θ ≤ 60 °C
            Ie / Max. rated operational current AC-3 (1)
                                     220-230-240 V 9 A              12 A                  15.7 A
                                          400 V 9 A                 12 A                  15.5 A
              M    3-phase motors         415 V 9 A                 12 A                  15.5 A
             3                            440 V 8 A                 11 A                  13.6 A
                                          500 V 8 A                 11 A                  12.5 A
                                          690 V 5 A                 7 A                   9 A
            Rated operational power AC-3 (1)
                                     220-230-240 V 2.2 kW           3 kW                  4 kW
                                          400 V 4 kW                5.5 kW                7.5 kW
              M    1500 r.p.m. 50 Hz      415 V 4 kW                5.5 kW                7.5 kW
             3     1800 r.p.m. 60 Hz      440 V 4 kW                5.5 kW                7.5 kW
                   3-phase motors
                                                                                          7.5 kW
                                                                    5.5 kW
                                          500 V 4 kW
                                          690 V 4 kW                5.5 kW                7.5 kW
          Rated making capacity AC-3          10 x Ie AC-3 acc. to IEC 60947-4-1
          Rated breaking capacity AC-3        8 x Ie AC-3 acc. to IEC 60947-4-1
          AC-8a Utilization category
          (without thermal overload relay - Ue 400 V 50/60 Hz - θ ≤ 40 °C)
            Ie / Rated operational current AC-8a  12 A              16 A                  22 A
            Rated operational power AC-8a     5.5 kW                7.5 kW                11 kW
          Short-circuit protection device for contactors
          without thermal overload relay - Motor protection excluded (2)
          Ue ≤ 500 V AC - gG type fuse        25 A
          Rated short-time withstand current Icw  1 s 230 A         250 A                 250 A
          at 40 °C ambient temperature,   10 s 100 A                124 A                 124 A
          in free air from a cold state   30 s 65 A                 75 A                  75 A
                                          1 min 50 A                55 A                  55 A
                                         15 min 20 A                22 A                  22 A
          Maximum breaking capacity
          cos φ = 0.45                  at 440 V 155 A
                                        at 690 V 90 A
          Power dissipation per pole    Ie / AC-1 0.9 W             1.1 W                 1.1 W
                                        Ie / AC-3 0.18 W            0.33 W                0.55 W
          Max. electrical switching frequency  AC-1 600 cycles/h
                                          AC-3 1200 cycles/h
                                          AC-4 300 cycles/h
          (1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
          (2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".