Page 846 - ABB_Motor _Protection_and_Control_catalogue_20221216
P. 846

11/8             ABB  MOTOR PROTECTION AND CONTROL

          —

          HF0.6, HF2.4, HF9 electronic compact starters
          Direct-on-line starter




                                    The HF-DOL-range is used for the direct-on-line start of motors and the switching of non-resistive
                                    loads. With contactor and overload relay functionalities integrated into one device, the results are
                                    faster wiring times and fewer faults. The range covers 0.6 A, 2.4 A and up to 9 A - for motors up to
                                    3 kW – 400 V AC. The integrated electronic overload protection with tripping class 10A has a wide
                                    setting range that enables just three models to cover all requirements. The control supply voltage
                                    is 24 V DC. For the control and main connection points ABB offers screw connections.
                                    ABB also offers a HF-DOLE safety range with emergency stop function. This offers Safety Integrity
                                    Level 3, in accordance with functional safety standard IEC 61508-1 and Performance Level 'e' in
                                      accordance with ISO 13849-1 all in combination with a safety relay like ABB's Sentry SSR10. The
                        2CDC241009V0016  Rated    Rated   Rated   Setting    Full load  Type   Order code  Weight
                                    safety range is ATEX-certified.

                                    operational  operational
                                    current    power  operational  range  amps                             (1 pce)
                                                                  motor
                                                   current
          HF9-DOL-24VDC             AC-53a  AC-53a  AC-51         use
                                    A      kW      A       A      A                                        kg
                                    Direct-on-line starter with overload protection
                                    0.6    0.18 (400V)  0.6  0.075 … 0.6  0.6  HF0.6-DOL-24VDC  1SAT112000R1011  0.205
                                    2.4    0.75 (400V)  2.4  0.18 … 2.4   2.4  HF2.4-DOL-24VDC  1SAT122000R1011  0.218
                                    6.5    3.00 (400V)  9.0  1.5 … 9.0  6.5  HF9-DOL-24VDC  1SAT142000R1011  0.206
                                    Direct-on-line starter with overload protection and emergency stop
                                    0.6    0.18 (400V)  0.6  0.075 … 0.6  0.6  HF0.6-DOLE-24VDC  1SAT113000R1011  0.205
                                    2.4    0.75 (400V)  2.4  0.18 … 2.4   2.4  HF2.4-DOLE-24VDC  1SAT123000R1011  0.218
                                                           1.5 … 9.0
                                                   9.0
                                                                  6.5
                                                                                      1SAT143000R1011
                                                                        HF9-DOLE-24VDC
                                                                                                           0.206
                                    6.5
                                           3.00 (400V)
                        2CDC241012V0016
          HF9-DOLE-24VDC










   11










                                  Main dimensions mm, inches










                                                                               2CDC242003F0017



                                  HF0.6, HF2.4, HF9
   841   842   843   844   845   846   847   848   849   850   851