          Protection and safety
          Data & signal protection
          OVR SL X Series


          OVR SL X Series - Technical specification
          Electrical specification                        OVR SL15X                    OVR SL30X
          ABB order code                                  7TCA085400R0386              7TCA085400R0387                 5
          Nominal voltage  (1)                            15 V                         30 V
          Maximum working voltage Uc (RMS/DC)  (2)        11 V/16.7 V                  25 V/36.7 V
          Current rating (signal)                         750 mA
          In-line resistance (per line ±10%)              1.0 Ω
          Bandwidth (-3 dB 50 Ω system)                   45 MHz
          Intrinsically safe specification                OVR SL15X                    OVR SL30X
          Maximum voltage Ui                              30 V
          Maximum power Pi      – Per -40 °C < Ta < 40 °C  1.3 W
                                – Per -40 °C < Ta < 60 °C  1.2 W
                                – Per -40 °C < Ta < 80 °C  1.0 W
          Capacitance Ci                                  0 μF
          Inductance Li                                   0 μH
          Certificate number                              IECEx SIR 10.0030X, Sira 10ATEX2063X
          Classification                                  Ex II 2 (1) G, Ex ia (ia Ga) IIC T4 Gb
          Transient specification                         OVR SL15X                    OVR SL30X
          Let-through voltage (all conductors)   Up
                                    (3)
          C2 test 4 kV 1.2/50 μs, 2 kA 8/20 μs to BS EN/EN/IEC 61643-21  38.4 V        63.0 V
          C1 test 1 kV, 1.2/50 μs, 0.5 kA 8/20 μs to BS EN/EN/IEC 61643-21  29.4 V     51.3 V
          B2 test 4 kV 10/700 μs to BS EN/EN/IEC 61643-21  26.8 V                      45.4 V
          5 kV, 10/700 μs  (4)                            27.5 V                       46.3 V
          Maximum surge current
          D1 test 10/350 μs to BS EN/EN/  – Per signal wire  1.25 kA
          IEC 61643-21            – Per pair              2.5 kA
          8/20 μs to ITU-T K.45:2003,    – Per signal wire  10 kA
          IEEE C62.41.2:2002
                                  – Per pair              20 kA
          Mechanical specification                        OVR SL15X                    OVR SL30X
          Temperature range                               -40 to +80 °C
          Connection type                                 Screw terminal - maximum torque 0.8 Nm
          Conductor size (stranded)                       4 mm 2
          Earth connection                                Via DIN rail or 4 mm  earth terminal - maximum torque 0.8 Nm
                                                                        2
          Case material                                   FR Polymer UL-94 V-0
          Weight                  – Unit                  0.08 kg
                                  – Packaged (per 10)     0.85 kg
          Dimensions                                      See diagram below











                                                                                                            104.6 mm
          (1)   Nominal voltage (RMS/DC or AC peak)
           measured at < 10 μA                                           106.5 mm
          (2)   Maximum working voltage (RMS/DC or AC peak)
           measured at < 1 mA leakage                     7 mm    2  S  1           1  S  2  E
          (3)   The maximum transient voltage let-through of the
           protector throughout the test (±10%), line to line &
           line to earth, both polarities. Response time < 10 ns
          (4)   Test to IEC 61000-4-5:2006, ITU-T (formerly
           CCITT) K.20, K.21 and K.45, Telcordia
           GR-1089-CORE, Issue 2:2002, ANSI TIA/EIA/
           IS-968-A:2002 (formerly FCC Part 68)