          Protection and safety
          Mains power protection
          OVR 240-16A






  5
                                            Combined Type 2 and 3 tested protector (to BS EN 61643) for use on low
                                            current (up to  16 A) single phase systems to protect connected electronic
                                            equipment from transient overvoltages on the mains supply, e.g. CCTV systems,
                                            fire/intruder alarm panels.





          Features & benefits
          •  Very low let-through voltage (enhanced protection to    •  Removable DIN rail foot for simple clip-on mounting to top
           IEC/BS EN 62305) between all sets of conductors (phase   hat DIN rails
           to neutral, phase to earth, neutral to earth - Full Mode   •  Colour coded terminals give a quick and easy installation
           protection) allowing continuous operation of equipment  check - grey for the dirty (line) end and green for the clean
          •  Repeated protection in lightning intense environments  end
          •  Compact size for easy incorporation in the protected   •  Robust housing and substantial earth stud fixing holes
           system                                              ready for flat mounting
                                                              •  Maintenance free

          Application                                         Installation
          Use these protectors on low current mains power supplies,   Connect in-line with the power supply usually either within
          e.g. CCTV cameras, alarm panels and telemetry equipment.  the equipment panel (or for CCTV cameras, in an enclosure
                                                              close by), or on the fused connection that supplies
                                                              equipment. To protect equipment inside a building from
                                                              transients entering on an outgoing feed (e.g. to CCTV
                                                              cameras or to site lighting) the protector should be installed
                                                              as close to where the cable leaves the building as possible.
                                                              Protectors should be installed either within an existing
                                                              cabinet/cubicle or in a separate enclosure.


          Accessories                                         Connect in-line on supplies fused up to 16 A.
          If several OVR 240-16A protectors are to be installed together, or if one is in use   Note how the protector can also be
          alongside OVR SPDs for video or signal lines, these can be simultaneously mounted   earthed from its earth stud.
          and earthed on a OVR CME kit and housed in a suitable OVR WBX enclosure.
                                                                   Earth
                                                                DIRTY                                                                 CLEAN




                                                                    From              To
                                                                    line              equipment