Page 39 - IDEC timer catalogue
P. 39
Timers GT3F Series
Instructions: Setting GT3F Series Timers
POWER Indicator Switches & Pilot Lights
l Setting Knob
j Dial Selector k Time Range Selector
0-1, 0-3, 0-6, 0-18, 0-60 1S, 10S
Step 1 Desired Operation Selection Remarks Display Lights
Base Time Ranges j Dial Selector k Time Range Selector
0.1s to 1s 0 to 1
0.1s to 3s 0 to 3 1s
Select a time Time range can be selected from 1S and 10S using a fl at screwdriver and fi ve
range that 0.1s to 6s 0 to 6 different dials of 0 to 1, 0 to 3, 0 to 6, 0 to 18, and 0 to 60 are displayed in the six
contains the 0.1s to 10s 0 to 1 windows by turning the Dial Selector, allowing for selecting the best suited scale.
desired period 0.3s to 30 0 to 3 Note that the switch does not turn infi nitely.
of time. Relays & Sockets
0.6s to 60 0 to 6 10s
1.8s to 180s 0 to 18
6s to 600s 0 to 60
Step 2 Remarks
Setting Examples:
1. When the Setting Knob l is set at 2.5, with Dial Selector j 0 to 3 and Time
Range Selector k 1S selected, then the set time is 2.5 seconds.
The set time is selected by turning the l Setting Knob.
2. When the Setting Knob l is set at 5.0,
with Dial Selector j 0 to 60 and Time Range Selector k 10S selected, then the Timers
set time is 500 seconds. Terminal Blocks