         Technical data
         OTDC S2.0-Series for higher short-circuit currents IEC












          —
          Technical data according to IEC 60947 for switch-disconnectors OTDC100G_…250G_-ESS
          Switch size                                       A   OTDC100G_-ESS OTDC160G_-ESS OTDC200G_-ESS OTDC250G_-ESS
          Rated insulation voltage U  Pollution degree 2    V   1500        1500        1500        1500               04
                           i
          Rated impulse withstand voltage                   kV  12          12          12          12
          Rated thermal current I th  1)  In open air, normal conditions  2)  A  100  160  200      250
                                In enclosure 40°C           A   100         160         200         250
                                In enclosure 50°C           A   100         160         200         250
                                In enclosure 60°C           A   100         160         200         219
                                In enclosure 70°C           A   100         146         169         185
                                In enclosure 80°C           A   88          115         133         146
          ...with cable or bar cross section  Cu            mm² 35          70          95          120
          Rated operational   DC-21B  1000V  1 circuit  2P (1P+, 1P-)  A  100  160      200         250
          current Ie ,                   2 circuits  4P (2P+, 2P-)  A  100  160         200         250
                 5)
          poles in series
                                1500V    1 circuit  2P (1P+, 1P-)  A  100   160         200         250
                                         2 circuits  4P (2P+, 2P-)  A  100  160         200         250
                        DC-PV1  1000V    1 circuit  2P (1P+, 1P-)  A  100   160         200         200
                                         2 circuits  4P (2P+, 2P-)  A  100  160         200         200
                                1500V    1 circuit  2P (1P+, 1P-)  A  100   160         200         200
                                         2 circuits  4P (2P+, 2P-)  A  100  160         200         200
                        DC-PV2  1000V    1 circuit  2P (1P+, 1P-)  A  100   160         200         200
                                         2 circuits  4P (2P+, 2P-)  A  100  160         200         200
                                1500V    1 circuit  2P (1P+, 1P-)  A  100   100         100         100
                                         2 circuits  4P (2P+, 2P-)  A  100  100         100         100
          Rated short-time withstand   R.M.S. -value I cw   kA  10          10          10          10
          current, 1500V, 0,1
          Rated short circuit making   Peak value I cm      kA  10          10          10          10
          capacity, 1500V
          Rated conditional short-circuit   R.M.S. - value Iq  kA  50       50          50          50
          current Iq            Max. fuse size              A   100         160         200         250
          Required protection  3)
          Power loss/pole       At rated current            W   1,0...1,3   3,1...3,5   5,0...5,5   7,7...8,4
          Terminal bolt size    Metric thread diameter x length  mm M8x25   M8x25       M8x25       M8x25
          Terminal tightening torque  Counter torque required  Nm  15…22    15…22       15…22       15…22
          Mechanical Endurance  Cycles                      -   10.000
          Operating altitude without                        m   ≤2000
          derating
          Operating torque      2P                          Nm  6…9         6…9         6…9         6…9
          1)  For more detailed derating please consult us. Installation condition may have an influence on the derating by increasing the possible rated current. The given deratings are a
          reference based on specific test setup.
          2)  Normal conditions defined in IEC 60947-1, section 6.1.
          3)  Please consult us on the fuse coordination table for more information.
          4)  For DC-22B utilization category ratings, please consult us.














          —