Page 34 - OTDC Switch
P. 34

34               SWITCH-DISCONNECTORS OTDC AND OTDCP

         —

         Ordering information, IEC and UL
         OTDC S2.0-Series 100…250A















                           Robust DC switch-disconnector for up to 1500V DC applications covering 100-250A current range. The
                           new design has a more compact size, higher efficiency and higher performance. The two-pole 1500V
                           DC concept helps manufacturers improve system efficiency, reducing switch power losses up to 75%.
                           The physical footprint is up to 70%  smaller than other solutions in the market. The compact size of the
                           new OTDC range makes it possible for manufacturers to reduce the size of enclosures. Handles, shafts
          —                or other hardware are not included.
          OTDC100...250_GV11
                        —
                        IEC Ordering information
                               Rated
                               operational    Number   Number
                        Voltage   Current [A]  of   Circuit  of   Single package     Bulk package
                        [V DC]  DC-21B DC-PV2  Circuits   1)  poles  Type  2)  Order code  Type  3)  Order code
                        Front operated, mechanism between the poles
                        1500   100   100   1     2a, 2b  2   OTDC100GV11  1SCA161932R1001 OTDC100GV11/280  1SCA162002R1001
                        1500   160   100   1     2a, 2b  2   OTDC160GV11  1SCA161933R1001 OTDC160GV11/280  1SCA162004R1001
                        1500   200   100   1     2a, 2b  2   OTDC200GV11  1SCA161938R1001 OTDC200GV11/280  1SCA162005R1001
                        1500   250   100   1     2a, 2b  2   OTDC250GV11  1SCA161996R1001 OTDC250GV11/280  1SCA162007R1001
                        1500   100   100   2     4a, 4c  4   OTDC100GV22  1SCA161976R1001
                        1500   160   100   2     4a, 4c  4   OTDC160GV22  1SCA161985R1001
                        1500   200   100   2     4a, 4c  4   OTDC200GV22  1SCA161989R1001
                        1500   250   100   2     4a, 4c  4   OTDC250GV22  1SCA161939R1001
                        Side operated, mechanism at the end of the switch
                        1500   100   100   1     2a, 2b  2   OTDC100GV02S  1SCA161974R1001
                        1500   160   100   1     2a, 2b  2   OTDC160GV02S  1SCA161982R1001
                        1500   200   100   1     2a, 2b  2   OTDC200GV02S  1SCA161986R1001
                        1500   250   100   1     2a, 2b  2   OTDC250GV02S  1SCA161995R1001

                        —
                        UL Ordering information
                              Rated
                              operational   Number      Number
                        Voltage   Current [A]  of    Circuit  of  Single package      Bulk package
                        [V DC]  UL98B IEC60947-3  Circuits   1)   poles  Type  2)  Order code  Type  3)  Order code
                        Front operated, mechanism between the poles
                        1500  100  160      1    2a, 2b  2    OTDC100UGV11  1SCA161978R1001 OTDC100UGV11/280 1SCA162003R1001
                        1500  200  250      1    2a, 2b  2    OTDC200UGV11  1SCA161991R1001 OTDC200UGV11/280 1SCA162006R1001
                        1500  250  250      1    2a, 2b  2    OTDC250UGV11  1SCA161942R1001 OTDC250UGV11/280 1SCA162008R1001
                        1500  100  160      2    4a, 4c  4    OTDC100UGV22  1SCA161981R1001
                        1500  200  250      2    4a, 4c  4    OTDC200UGV22  1SCA161994R1001
                        1500  250  250      2    4a, 4c  4    OTDC250UGV22  1SCA162001R1001
                        Side operated, mechanism at the end of the switch
                        1500  100  160      1    2a, 2b  2    OTDC100UGV02S 1SCA161977R1001
                        1500  200  250      1    2a, 2b  2    OTDC200UGV02S 1SCA161990R1001
                        1500  250  250      1    2a, 2b  2    OTDC250UGV02S 1SCA161940R1001
                        * Please consult us for 1000V DC types.
                        1)  Please see floating circuit in page 36 and grounded circuits in pages 56-57. Single circuit 1a and Double circuit 3 with connection bar kit accessories.
                        2)  Phase barriers are included to pole configurations _22/_02 – Installation mandatory.
                        3)  Bulk package includes 280pcs of switches in FIN-pallet (LxWxH) 1200mm x 1000mm x 1200mm. The bulk package contains only switches and one
                        installation instruction.
                        You can find the accessories starting from page 47 and dimensional drawings starting from page 61.
   29   30   31   32   33   34   35   36   37   38   39