3/60             SACE TMAX XT LOW VOLTAGE MOLDED CASE CIRCUIT-BREAKERS



          —

          Ekip Touch/Hi-Touch


          Measurement functions and data










         Network Analyzer                                                                      Interval                         Ekip Touch       Ekip Touch Measuring  Ekip Hi-Touch  Ekip M Touch   Ekip G Touch    Ekip G Hi-Touch
         Hourly average voltage value             [V] [no] - Umin= 0.75…0.95 x Un              t = 5…120min                                                       ●                                                  ●
                                                        - Umax= 1.05…1.25 x Un
                                                        - Events counter  (1)
         Short voltage interruptions                [no] - Umin= 0.75…0.95 x Un                t <40ms                                                            ●                                                  ●
                                                        - Events counter  (1)
         Short voltage spikes                       [no] - Umax= 1,05…1,25 x Un                t <40ms                                                            ●                                                  ●
                                                        - Events counter  (1)
         Slow voltage sags and swells               [no] - Umin1= 0.75…0.95 x Un               t = 0.02s...60s                                                    ●                                                  ●
                                                        - Umin2= 0.75…0.95 x Un
                                                        - Umin3= 0.75…0.95 x Un
                                                        - Umax1= 1.05…1.25 x Un
                                                        - Umax2= 1.05…1.25 x Un
                                                        - Events counter  (1)
         Voltage unbalance                        [V] [no] - U neg. seq.= 0.02…0.10 x Un       t = 5…120min                                                       ●                                                  ●
                                                        - Events counter  (1)
         Harmonic analysis                              Current and Voltage                                                                                       ●                                                  ●
                                                        - up to 50 th
                                                        - Alarm THD: 5…20%
                                                        - Single harmonic alarm:
                                                        3...10% plus a count of minutes the harmonic has been
                                                        exceeded
         Record of values: for each interval with time-stamping  Parameters                    Window & interval
         Current: minimum and maximum                [A] I Min, I Max                          Fixed synchronizable             ●                ●                ●                ●                ●                ●
         Phase-to-phase voltage: minimum and maximum  [V] U Min, U max                         by remote                          (2)            ●                ●                ●                ●                ●
         Active power: average and maximum          [kW] P Mean, P Max                         Duration: 5…120min                 (2)            ●                ●                ●                ●                ●
         Reactive power: average and maximum      [kVAR] Q Mean, Q Max                         Number of intervals:               (2)            ●                ●                ●                ●                ●
         Apparent power: average and maximum       [KVA] S Mean, S Max                         24                                 (2)            ●                ●                ●                ●                ●
         Data logger: high rate sampling record of  parameters  Parameters
         Currents                                    [A] L1, L2, L3, Ne, Ig                    Fixed synchronizable                                               ●                                 ●                ●
         Voltages                                    [V] U12, U23, U31                         by remote                                                          ●                                 ●                ●
         Sampling rate                              [Hz] 1200-9600                             Duration: 5…120min                                                 ●                                 ●                ●
         Maximum recording duration                  [s] 18                                    Number of intervals:                                               ●                                 ●                ●
         Recording stop delay                        [s] 0-10s                                 24                                                                 ●                                 ●                ●
         Number of registers                        [no] 2 independent                                                                                            ●                                 ●                ●

         Info on trip & opening data: after a fault without auxiliary supply  Parameters
         Type of protection tripped                     eg. L, S, I, G, UV, OV                                                  ●                ●                ●                ●                ●                ●
         Fault values per phase                  [A/V/Hz  eg. I1, I2, I3, neutral for S protection                              ●                ●                ●                ●                ●                ●
                                                  w/VAR] V12, V23, V32 for UV protection
         Time-stamping                                  Date, time and progressive number                                       ●                ●                ●                ●                ●                ●

         Maintenance indicators                         Parameters
         Information on last 30 trips                   Type of protection, fault values and time-stamping                      ●                ●                ●                ●                ●                ●
         Information on last 200 events                 Type of event, time-stamping                                            ●                ●                ●                ●                ●                ●
         Number of mechanical operations            [no] can be associated to alarm                                             ●                ●                ●                ●                ●                ●
         Total number of trips                      [no]                                                                        ●                ●                ●                ●                ●                ●
         Total operating time                        [h]                                                                        ●                ●                ●                ●                ●                ●
         Wear of contacts                           [%] Pre-alarm >80%                                                          ●                ●                ●                ●                ●                ●
                                                        Alarm = 100%
         Date of maintenance operations performed       Last                                                                    ●                ●                ●                ●                ●                ●
         Indication of maintenance operation needed                                                                             ●                ●                ●                ●                ●                ●
         Circuit-breaker I.D.                           Type of circuit-breaker, assigned device name, serial                   ●                ●                ●                ●                ●                ●
                                                        number
         Self-diagnosis                                 Parameters
         Check of continuity of internal connnections   Alarm due to disconnection: rating plug, sensors,   Note: Opening of the   ●             ●                ●                ●                ●                ●
                                                        trip coil                              circuit-breaker can be
         Failure of circuit-breaker to open (ANSI 50BF)  Alarm following non-tripping of protection functions  set in the event of   ●           ●                ●                ●                ●                ●
         Temperature (OT)                               Pre-alarm and alarm for abnormal temperature  alarm                     ●                ●                ●                ●                ●                ●
         ● Available as standard                                                                                                1) No. of events day by day in the last year plus the total events in the breaker's lifetime
           Available as software package to be ordered via ABB Ability Marketplace TM  or during the circuit-breaker ordering phase. To add this function, the Measuring package must    2) Available only if Measuring package is enabled
             be installed first.