3/58             SACE TMAX XT LOW VOLTAGE MOLDED CASE CIRCUIT-BREAKERS



          —

          Ekip Touch/Hi-Touch


          Measurement functions and data









                           The parameters measurable for each trip unit are shown in the following tables. Three different soft-
                           ware packages are available to upgrade the trip units:
                           •  Measuring package for measurement of voltage, power and energy
                           •  Datalogger for data record
                           •  Network Analyzer for the evaluation of the power quality.

          Instantaneous measurements                  Ekip Touch  Ekip Touch   Ekip   Ekip M   Ekip G   Ekip G
                                                                Measuring  Hi-Touch  Touch   Touch    Hi-Touch
          Currents (RMS)            L1, L2, L3, Ne  [A] ●       ●        ●         ●         ●        ●
         Ground fault current (RMS)  Ig            [A] ●        ●        ●         ●         ●        ●

         Measuring package
         Phase-phase voltage (RMS)  U12, U23, U31  [V]          ●        ●         ●         ●        ●
          Phase-neutral voltage (RMS)  U1, U2, U3  [V]          ●        ●         ●         ●        ●
          Phase sequence                                        ●        ●         ●         ●        ●
          Frequency                 f             [Hz]          ●        ●         ●         ●        ●
          Active power              P1, P2, P3,   [kW]          ●        ●         ●         ●        ●
                                    Ptot
          Reactive power            Q1, Q2, Q3,   [kVAR]        ●        ●         ●         ●        ●
                                    Qtot
          Apparent power            S1, S2, S3, Stot  [KVA]     ●        ●         ●         ●        ●
          Power factor              PF1, PF2, PF3,              ●        ●         ●         ●        ●
                                    PF total
          Peak factor               total                       ●        ●         ●         ●        ●
          Active energy             Ep total,    [kWh]          ●        ●         ●         ●        ●
                                    Ep positive,
                                    Ep negative
          Reactive energy           Eq total,   [kVARh]         ●        ●         ●         ●        ●
                                    Ep positive,
                                    Ep negative
          Apparent energy           Es total     [KVAh]         ●        ●         ●         ●        ●