Combined Arresters – Type 1 + Type 2

           DEHNventil M TNC (FM)                                                                            951 300  951 305   DV M TNC 255
                                                                                                             DV M TNC 255 FM
           Modular combined lightning current and surge arrester for TN-C systems with a nominal voltage of 230 / 400 V (3+0 configuration);
           FM version with floating remote signalling contact.                                              951 300    951 305          4013364108134  04 01 01 01   970 g  962 g
                                                                                                             906,20 €
                                                                                                             4013364108141  04 01 01 01
                                                                                                             980,80 €
           Type DV M ...                     TNC 255                  TNC 255 FM
           Part No.                          951 300                  951 305
           SPD according to EN 61643-11 / IEC 61643-11  type 1 + type 2 / class I + class II   type 1 + type 2 / class I + class II
           Max. continuous operating voltage (a.c.)  (UC)  264 V (50 / 60 Hz)   264 V (50 / 60 Hz)
           Lightning impulse current (10/350 µs)   75 kA              75 kA
                [L1+L2+L3-PEN]  (Itotal)
           Lightning impulse current (10/350 µs) [L-PEN]  (Iimp)  25 kA  25 kA
           Voltage protection level  (UP)    ≤ 1.5 kV                 ≤ 1.5 kV
           Max. backup fuse (L) up to IK = 50 kArms  315 A gG         315 A gG
           Approvals                         KEMA, VDE, UL            KEMA, VDE, UL                                   Combined Arresters – Type 1 + Type 2
           Type of remote signalling contact  —                       changeover contact
                                             For use in switchgear installations with prospective short-circuit currents
           Extended technical data:
                                             of more than 50 kArms (tested by the German VDE)
           – Max. prospective short-circuit current  100 kArms (220 kApeak)    100 kArms (220 kApeak)


           DEHNventil M TNS (FM)                                                                            951 400  951 405   DV M TNS 255
                                                                                                             DV M TNS 255 FM
           Modular combined lightning current and surge arrester for TN-S systems with a nominal voltage of 230 / 400 V (4+0 configuration);
           FM version with floating remote signalling contact.                                              951 400  kg  951 405  kg        4013364108158  04 01 01 01   1.35  1.36

                                                                                                              1.196,20 €
                                                                                                             4013364108165  04 01 01 01

                                                                                                              1.295,30 €
           Type DV M ...                     TNS 255                  TNS 255 FM
           Part No.                          951 400                  951 405
           SPD according to EN 61643-11 / IEC 61643-11  type 1 + type 2 / class I + class II   type 1 + type 2 / class I + class II
           Max. continuous operating voltage (a.c.)  (UC)  264 V (50 / 60 Hz)   264 V (50 / 60 Hz)
           Lightning impulse current (10/350 µs)
                [L1+L2+L3+N-PE]  (Itotal)    100 kA                   100 kA
           Lightning impulse current (10/350 µs) [L, N-PE]  (Iimp)  25 kA  25 kA
           Voltage protection level [L-PE]/[N-PE]  (UP)  ≤ 1.5 / ≤ 1.5 kV   ≤ 1.5 / ≤ 1.5 kV
           Max. backup fuse (L) up to IK = 50 kArms  315 A gG         315 A gG
           Approvals                         KEMA, VDE, UL            KEMA, VDE, UL
           Type of remote signalling contact  —                       changeover contact
                                             For use in switchgear installations with prospective short-circuit currents
           Extended technical data:
                                             of more than 50 kArms (tested by the German VDE)
           – Max. prospective short-circuit current  100 kArms (220 kApeak)    100 kArms (220 kApeak)

           DEHNventil M TT (FM)                                                                             951 310  951 315   DV M TT 255
                                                                                                             DV M TT 255 FM
           Modular combined lightning current and surge arrester for TT and TN-S systems with a nominal voltage of 230 / 400 V (3+1 configuration);
           FM version with floating remote signalling contact.                                              951 310  kg  951 315  kg        4013364108172  04 01 01 01   1.27  1.28
                                                                                                              1.266,50 €

                                                                                                             4013364108189  04 01 01 01
                                                                                                              1.366,80 €

           Type DV M ...                     TT 255                   TT 255 FM
           Part No.                          951 310                  951 315
           SPD according to EN 61643-11 / IEC 61643-11  type 1 + type 2 / class I + class II   type 1 + type 2 / class I + class II
           Max. continuous operating voltage (a.c.) [L-N]  (UC)  264 V (50 / 60 Hz)   264 V (50 / 60 Hz)
           Lightning impulse current (10/350 µs)    100 kA            100 kA
                [L1+L2+L3+N-PE]  (Itotal)
           Lightning impulse current (10/350 µs) [L-N]/[N-PE]  (Iimp) 25 / 100 kA  25 / 100 kA
           Voltage protection level [L-N]/[N-PE]  (UP)  ≤ 1.5 / ≤ 1.5 kV   ≤ 1.5 / ≤ 1.5 kV
           Max. backup fuse (L) up to IK = 50 kArms  315 A gG         315 A gG
           Approvals                         KEMA, VDE, UL            KEMA, VDE, UL
           Type of remote signalling contact  —                       changeover contact
           Extended technical data:
           Voltage protection level [L-PE]  (UP)  2.2 kV              2.2 kV
                                             For use in switchgear installations with prospective short-circuit currents
                                             of more than 50 kArms (tested by the German VDE)
           – Max. prospective short-circuit current  100 kArms (220 kApeak)    100 kArms (220 kApeak)
















           Valid as of August 1, 2020                         You will find detailed product information on our website   23