Combined Arresters – Type 1 + Type 2
                                                                                                CIRCUIT INTERRUPTION
                                                                                                FUSE INTEGRATED
        DEHNvenCI
                                                             • Spark-gap based combined lightning current and surge arrester
                                                               with integrated lightning current carrying backup fuse
                                                             • Energy coordination with other arresters of the Red/Line
                                                               product family
                                                             • Low voltage protection level UP ≤ 1.5 kV (including backup fuse)
                                                             • Maximum system availability due to RADAX Flow follow
                                                               current limitation
    Combined Arresters – Type 1 + Type 2                     • High lightning current discharge capacity of 25 kA (10/350 µs)
                                                             • Extinction of mains follow currents up to 100 kArms

                                                             • Capable of protecting terminal equipment
                                                             • Operating state / fault indication by green / red indicator flag
                                                               in the inspection window

                                                             DEHNvenCI 1 255:
                                                                              Single-pole combined lightning current and
        For protecting low-voltage consumer installations against surges and even direct
        lightning strikes. For installation in conformity with the lightning protection zone
                                                                              surge arrester with integrated backup fuse
        concept at the boundaries from 0A – 2.
                                                             DEHNvenCI 1 255 FM: With remote signalling contact for  monito-
                                                                              ring device (floating changeover contact)
        Featuring the functional Red/Line family design, coordinated DEHNvenCI   The patented RADAX Flow technology for follow current limitation and
        combined lightning current and surge arresters provide maximum system   extinction ensures the high availability of the electrical consumer instal-
        protection and take up little space. The features of the practice-proven   lation to be protected.
        DEHNventil family were combined with a lightning current carrying arrest-  Even in case of short-circuit currents as high as 100 kArms, DEHNvenCI can
        er backup fuse in an enclosure with a width of only two modules.  be used in industrial systems without restrictions.
        Due to the increasingly compact design of switchgear installations, the   The ability to carry lightning impulse currents without destruction and
        standard-compliant installation of lightning current arresters is difficult   simultaneously reduce the energy to an acceptable level for terminal de-
        for the user. The DEHNvenCI not only meets requirements regarding the   vices ensures the availability of the switchgear installation in case of a
        space-saving integration of a combined lightning current and surge ar-  lightning strike. This considerably reduces the risk of cost-intensive fail-
        rester, but also satisfies the protection requirements of modern switchgear   ures.
        installations. The integrated arrester backup fuse is dimensioned to ensure
        maximum discharge capacity and optimal system protection.  The operating state / fault indicator of DEHNvenCI, which houses the fuse
                                                             monitoring system and does not cause operating currents, shows the op-
        The need to select and install an arrester backup fuse is eliminated, en-  erating state of the arrester. Apart from the standard visual indicator with
        suring short connecting cable lengths as required in IEC 60364-5-53.  green and red indicator flags, DEHNvenCI 1 255 FM devices feature a
        Consequently, DEHNvenCI is an efficient combined arrester which is easy   three-pole remote signalling terminal. As the remote signalling contact is
        to install.                                          designed as a floating changeover contact, the remote signal can, depend-
        The energy-coordinated arresters even allow protection of terminal devic-  ing on the circuit concept, be used as a make or break contact.
        es or sensitive electronic systems in modern switchgear installations if the
        distance between DEHNvenCI and the loads is ≤ 10 m.




        961 200   DVCI 1 255
        961 205   DVCI 1 255 FM  DEHNvenCI 255 (FM)
                         Single-pole combined lightning current and surge arrester with integrated lightning current carrying backup fuse for use in 230 / 400 V systems;
        961 200   4013364145108  04 01 01 03   432 g
              337,40 €   FM version with floating remote signalling contact.
        961 205   4013364145115  04 01 01 03   435 g
              353,30 €
                          Type DVCI 1 ...                   255                      255 FM
                          Part No.                          961 200                  961 205
                          SPD according to EN 61643-11 / IEC 61643-11  type 1 + type 2 / class I + class II   type 1 + type 2 / class I + class II
                          Maximum continuous operating voltage (a.c.)  (UC)  255 V (50 / 60 Hz)   255 V (50 / 60 Hz)
                          Lightning impulse current (10/350 µs)  (Iimp)  25 kA       25 kA
                          Voltage protection level  (UP)    ≤ 1.5 kV                 ≤ 1.5 kV
                          Max. mains-side overcurrent protection  not required       not required
                          Approvals                         KEMA                     KEMA
                          Type of remote signalling contact  —                       changeover contact
                                                            For use in switchgear installations with prospective short-circuit currents
                          Extended technical data:
                                                            of more than 50 kArms (tested by the German VDE)
                          – Max. prospective short-circuit current  100 kArms (220 kApeak)    100 kArms (220 kApeak)


                         Accessories for DEHNvenCI
                         Earthing Clip for two-module Enclosures, single-phase, two-pole / three-pole / four-pole
        900 419   EB 1 2 5
        900 419   4013364156821  04 01 02 50   39 g
              12,40 €
                         Earthing clip for connecting the earth terminal of e.g. two / three / four SPDs with two-module enclosure to earth, with terminal.
                          Type                              EB 1 2 5         EB DG 1000 1 3   EB 1 4 9
        900 411   EB DG 1000 1 3
        900 411   4013364107205  04 01 01 50   54 g
              15,10 €     Part No.                          900 419          900 411          900 417
                          Dimensions                        34 x 77 x 28 mm  34 x 112 x 28 mm  34 x 148 x 28 mm