Page 47 - Surge-Protection-E_0.pdf
P. 47

Coordinated Lightning Current Arresters – Type 1 for d.c. Applications
                                                                                                   WBF
                                                                                                   DEHN-FUNKENSTRECKEN-TECHNOLOGIE INSIDE
                                                                                                  WELLENBRECHER-FUNKTION
           DEHNsecure modular
           • Coordinated spark-gap-based lightning current arrester
            consisting of a base part and a plug-in protection module
           • Spark gap technology particularly suited for use in d.c. circuits
           • High lightning current discharge capacity of 25 kA (10/350 µs)
           • Directly coordinated with DEHNguard SE DC ... surge
            protective devices
           • Low voltage protection level
           • Operating state / fault indication by green / red indicator flag
            in the inspection window
           • Easy replacement of protection modules due to module
            locking system with module release button


                                                                For protecting d.c. consumer installations against surges and even direct lightning
                                                                strikes. For installation in conformity with the lightning protection zone concept at
                                                                the boundaries from 0A – 1.


           DEHNsecure M 1 ...:    Coordinated and modular single-pole lightning current arrester for d.c. applications
           DEHNsecure M 1 ... FM:   With remote signalling contact for monitoring device (floating changeover contact)
           DEHNsecure M 2P ...:    Coordinated and modular two-pole lightning current arrester for d.c. applications
           DEHNsecure M 2P ... FM:  With remote signalling contact for monitoring device (floating changeover contact)  Lightning Current Arresters – Type 1


           The modular devices of the DEHNsecure product family are coordinated   DEHNsecure M 1 242 (FM) is used for safety lighting systems. The rele-
           lightning current arresters with a functional design.  vant consumers are supplied with a.c. voltage during normal operation
           They can be energy-coordinated with type 2 surge arresters of the   and with battery-operated d.c. voltage during emergency operation. As
           DEHNguard SE DC family.                              surges may occur during both operating states, DEHNsecure M 1 242 is
           The DEHNsecure arresters combine high performance and ease of use in   suited for direct and alternating currents (backup fuse max. 10 A gG).
           a single device. Their electrical parameters are rated for the most stringent   The modular design of the DEHNsecure arresters makes them safe and
           requirements in lightning and surge protection systems.  user-friendly. Their vibration-proof module locking system, for example,
           The internal structure of the DEHNsecure spark gap is suited for use in d.c.   is said to be unique. Shock or vibration during transport or operation or
                                                                enormous mechanical impulse loads resulting from discharges do not
           circuits. The device concept prevents mains follow currents up to 25,000   affect the module locking system which ensures safe fixation both for the
           A d.c. from occurring.                               base part and protection module. Nevertheless, the protection modules
           With this new arrester series, a consistent lightning protection zone con-  can be easily replaced without tools by simply pressing the easy-to-use
           cept including the cross-boundary d.c. lines can now be implemented.  module release button. The mechanically coded base part and protection
           Furthermore, the leakage-current-free version of the spark-gap-based ar-  module avoid installing an incorrect module. DEHNsecure arresters
           rester offers numerous advantages when used in insulation monitored   incorporate double terminals, allowing series connection of the arresters
           systems or in applications where the highest demands are placed on     in a space-saving and cost-effective way according to IEC 60364-5-53
           self-energy consumption.                             requirements for nominal currents up to 125 A.
           DEHNsecure arresters are used, for example, in safety lighting systems,   The operating state / fault indicator of DEHNsecure does not cause oper-
           emergency power supplies, d.c. systems for direct supply of d.c. drives,   ating  currents and instantly  shows the operating  state  of the device.
           control circuits and any kind of battery-operated power supply.  Apart from the standard visual indicator with red and green indicator
           DEHNsecure M 1 60 (FM) and DEHNsecure M 2P 60 (FM) are specifi-  flags, DEHNsecure ... FM devices have an additional remote signalling
           cally developed for Remote Radio Head (RRH) applications. Designed for   output.  As  the  remote  signalling  contact  is  designed  as  a  floating
           possible high load currents, they leave sufficient spare capacity for future   changeover  contact,  the  remote  signal  can,  depending  on  the  circuit
           extensions in the field of mobile communication.     concept, be used as a make or break contact.






           DEHNsecure M 1 ...                                                                               971 121  971 120  971 122   DSE M 1 60 DSE M 1 220
                                                                                                             DSE M 1 242
           Coordinated and modular single-pole lightning current arrester for d.c. applications.
                                                                                                            971 121   4013364138582  04 01 01 12   284 g
                                                                                                                  255,90 €
                                                                                                            971 120   4013364133631  04 01 01 12   252 g
                                                                                                                  285,80 €
                                                                                                            971 122   4013364144477  04 01 01 12   258 g
                                                                                                                  315,60 €
           Type DSE M ...                       1 60            1 220           1 242
           Part No.                             971 121         971 120         971 122
           SPD classification according to EN 61643-11 / IEC 61643-11  type 1 / class I   type 1 / class I   type 1 / class I
           Max. continuous operating voltage (d.c.)  (UC)  60 V  220 V          242 V
           Lightning impulse current (10/350 µs)  (Iimp)  25 kA  25 kA          25 kA
           Voltage protection level  (UP)       ≤ 1.5 kV        ≤ 2.5 kV        ≤ 2.5 kV
           Max. mains-side overcurrent protection  250 A gL     250 A gL        250 A gL
           Approvals                            UL              —               —
           Extended technical data:                         when used in safety lighting systems
            – Max. continuous operating voltage (a.c.)  (UC)  —  —              255 V



           Valid as of August 1, 2020                         You will find detailed product information on our website   43