          ABB i-bus® KNX
          Movement and Presence Detection




                                                                                               Corridor
                                                            Mini                                        Corridor
                                                 Mini Basic          Basic   Premium    Sky     Basic
                                                          Premium                                       Premium
                                                 6131/20-  6131/21-  6131/30-  6131/31-  6131/40-  6131/50-  6131/51-
                                                  xxx-500  xxx-500  xxx-500  xxx-500  xxx-500  xxx-500  xxx-500
          General
          Supply voltage                           KNX      KNX      KNX      KNX      KNX      KNX       KNX
                                                  flush-   flush-    flush-   flush-   flush-   flush-   flush-
                                                 mounted/  mounted/  mounted/  mounted/  mounted/  mounted/  mounted/
          Type of installation
                                                  surface-  surface-  surface-  surface-  surface-  surface-  surface-
                                                 mounted  mounted  mounted   mounted  mounted  mounted  mounted
          Programming button accessible from outside                                –                 
                                                                                               Corridor:   Corridor:
                                                                                                only      only
          Detection range diameter (sitting / walking person)
                                                                                               walking   walking
                                                                                               person    person
                                                                                               Frontal:   Frontal:
                                                                                               max. 18 x   max. 18 x
                                                   Max.     Max.     Max.     Max.
          Installation height 2.5 m               5.0 m/   5.0 m/   8.0 m/   8.0 m/     –       2,5 m;   2,5 m;
                                                  6.5 m     6.5 m   10.0 m   10.0 m            Lateral:   Lateral:
                                                                                               max. 24 x   max. 24 x
                                                                                                2,5 m    2,5 m
                                                                                               Frontal:   Frontal:
                                                                                               max. 20 x   max. 20 x
                                                   Max.     Max.     Max.     Max.
          Installation height 3.0 m               6.5 m/   6.5 m/   10.0 m/   10.0 m/   –       3 m;      3 m;
                                                  8.0 m     8.0 m   12.0 m   12.0 m            Lateral:   Lateral:
                                                                                               max. 30 x   max. 30 x
                                                                                                 3 m      3 m
                                                                                               Frontal:   Frontal:
                                                                                               max. 20 x   max. 20 x
                                                   Max.     Max.     Max.     Max.
          Installation height 4.0 m               9.0 m/   9.0 m/   14.0 m/   14.0 m/   –       3 m;      3 m;
                                                  10.5 m   10.5 m   16.0 m   16.0 m            Lateral:   Lateral:
                                                                                               max. 30 x   max. 30 x
                                                                                                 3 m      3 m
          Installation height 6.0 m                 –        –        –        –     Max. 18.0 m  –        –
          Installation height 12.0 m                –        –        –        –     Max. 24.0 m  –        –
          Number of channels
          Movement detector                         2     4 in total  2      4 in total  2       2      4 in total
          Constant light switch                     2     4 in total  2      4 in total  2       2      4 in total     14
          Combination                             1 x each  4 in total  1 x each  4 in total  1 x each  1 x each  4 in total
          Constant light controller                 –        2        –        2        –         –        2
          Heating/cooling/ventilation systems (HVAC)  –      1        –        1        –         –        1
                                                          10 button         10 button   (only red       10 button
                                                            pairs             pairs    for activa-       pairs
          Infrared receiver, can be                 –     + 4 single   –    + 4 single   tion of the   –  + 4 single
          operated via IR remote control 6010-25          buttons/           buttons/   program-        buttons/
                                                          24 single          24 single   ming mode)     24 single
                                                           buttons           buttons                    buttons
          Two power-off stages
          Movement detector                                                                          
          Constant light control                    –                –                –         –        


          —
            = Function is supported
          –  =   Function is not supported