5/120            ELECTRICAL INSTALL ATION SOLUTIONS FOR BUILDINGS   2CHC 420 001 C0201




          —
          Protection and safety
          Data & signal protection
          OVR RTD Series






  5
                                            Combined Category D, C, B tested protector (to BS EN 61643) suitable for 3-wire
                                            RTD systems to protect monitoring equipment. For use at boundaries up to LPZ
                                            0 to protect against flashover (typically the service entrance location) through
                                            to LPZ 3. Available as standard OVR RTD format, or compact OVR RTDQ and Slim
                                            Line OVR SL RTD versions for installations where a high number of lines require
                                            protection.




         Features & benefits
         •  Protects all three wires on a 3-wire RTD system with   •   OVR RTD can be flat mounted on base or side
           a single protector                                 •    OVR RTD and OVR RTDQ have colour coded terminals for
         •   Very low let-through voltage (enhanced protection to    quick and easy installation check
           IEC/BS EN 62305) between all lines - Full Mode protection  •   OVR SL RTD has ultra slim 7 mm width ideal for compact
         •    Full Mode design capable of handling partial lightning   protection of large numbers of lines (e.g. process
           currents as well as allowing continual operation of   control installations)
           protected equipment                                •    OVR SL RTD includes two stage removable protection
         •    Repeated protection in lightning intense environments  module with simple quick release mechanism
         •    Low in-line resistance minimizes reductions in signal   allowing partial removal for easy line commissioning
           strength                                            and maintenance as well as full removal for
         •    Built-in DIN rail foot for simple mounting to top hat    protection replacement
           DIN rails
         •    Convenient earthing through DIN foot and/or earth   For further information on RTD applications, see separate
           terminal                                           Application Note OVR AN001 (contact us for a copy).


          Installation
          Connect in series with the signal line either near where it   point. Install protectors either within an existing
          enters or leaves the building or close to the equipment being   cabinet/cubicle or in a separate enclosure.
          protected ensuring it is very close to the system’s earth star




          Accessories                          OVR RTD installed in series         OVR SL RTD installed in series
          Replacement module for OVR SL RTD:
          OVR SLRTD/M                          DIRTY                                                      CLEAN  LINE                                                       CLEAN
                                                                                                         CLEAN
                                                                                      LINE
                                                                                               Lightning Barrier
          Standard module replacement
                                                                                               Nominal voltage  30V
          OVR SLRTD/B                                                               1          Current rating  750mA 1.0Ω 20kA 63V  3
                                                                                               Max working voltage, U c 36.7V
                                                                                               In-line resistance
                                                                                               Max surge current
                                                                                               Let-through voltage, U p
          Base replacement                                                                      Furse Wilford Road,
                                               From                  To             S           Nottingham,   S
                                                                                                NG2 1EB, UK
          Combined Mounting/Earthing kits for OVR RTD:  line  Earth  equipment      2                         4
          OVR CME 4 For up to 4 x OVR RTD
          OVR CME 8 For up to 8 x OVR RTD
          OVR CME 16 For up to 16 x OVR RTD    OVR RTDQ installed in series (in-line)
          OVR CME 32 For up to 32 x OVR RTD
                                                                                   From line         To equipment
                                                                                    From line
                                                                                                     To equipment
                                               DIRTY                                                      CLEAN
                                                                                               Earth
          If protectors cannot be incorporated within                                          Earth
          an existing panel or enclosure, OVR WBX
          enclosures are available for up to 4, 8, 16 or 32
          protectors and their associated OVR CME kit.
          Weatherproof enclosure:
          OVR WBX SLQ (OVR SLRTD and OVR RTD Q)
                                               From                   To
                                               line        Earth      equipment
          NOTE: For 2-wire or 4-wire RTD applications, use one or two OVR 06D or OVR SL06 protectors respectively.