          Electrical specification             OVR RTD               OVR SL RTD           OVR RTDQ
          ABB order code                       7TCA085400R0313       7TCA085400R0315      7TCA085400R0314              5
          Nominal voltage  (1)                 6 V
          Maximum working voltage Uc (RMS/DC)  (2)  5 V/7.79 V
          Current rating (signal)              200 mA                500 mA               700 mA
          In-line resistance (per line ±10%)   10 Ω                  1.0 Ω                1.0 Ω
          Bandwidth (-3 dB 50 Ω system)        800 kHz               1.5 MHz              800 kHz
          Transient specification              OVR RTD               OVR SL RTD           OVR RTDQ
                                    (3)
          Let-through voltage (all conductors)   Up
          C2 test 4 kV 1.2/50 μs, 2 kA 8/20 μs to    12.0 V          17.9 V               15.0 V
          BS EN/EN/IEC 61643-21
          C1 test 1 kV, 1.2/50 μs, 0.5 kA 8/20 μs to    11.5 V       12.1 V               12.5 V
           BS EN/EN/IEC 61643-21
          B2 test 4 kV 10/700 μs to BS EN/EN/IEC 61643-21  10.0 V    11.0 V               10.0 V
          5 kV, 10/700 μs  (4)                 10.5 V                11.3 V               10.5 V
          Maximum surge current
          D1 test 10/350 μs to    – Per signal wire  2.5 kA          1.25 kA              2.5 kA
          BS EN/EN/IEC 61643-21  – Per pair    5 kA                  2.5 kA               5 kA
          8/20 μs to ITU-T K.45:2003,  – Per signal wire  10 kA
          IEEE C62.41.2:2002  – Per pair       20 kA
          Mechanical specification             OVR RTD               OVR SL RTD           OVR RTDQ
          Temperature range                    -40 to +80 °C
          Connection type                      Screw terminal -      Screw terminal -     Pluggable 12 way screw
                                               max. torque 0.5 Nm    max. torque 0.8 Nm   terminal
          Conductor size (stranded)            2.5 mm 2              4 mm 2               2.5 mm 2
          Earth connection                     M6 stud - max. torque 0.5 Nm  Via DIN rail or 4 mm  earth   Via DIN rail or M5 threaded
                                                                                  2
                                                                     terminal - max. torque 0.8 Nm  hole in base of unit -
                                                                                          max. torque 0.6 Nm
          Case Material                        FR Polymer UL-94 V-0
          Weight            – Unit             0.08 kg               0.08 kg              0.1 kg
                            – Packaged (per 10)  0.85 kg             0.85 kg              1.3 kg
          Dimensions                           See diagram below



                                            OVR RTD                                OVR RTDQ          95 mm

                                                                              54 mm
                                                   38 mm                                        M3 clearance
                                                                                                Depth: 18 mm
                                                                105 mm                   87 mm            69 mm
                                                               M4 clearance
                                                                                                     42 mm
                                                                120 mm
                                                   19 mm
                                                                109 mm
                                                               M4 clearance
                                                                                   OVR SL RTD
          (1)   Nominal voltage (RMS/DC or AC peak)
           measured at < 200 μA
          (2)   Maximum working voltage (RMS/DC
           or AC peak) measured at < 10 mA
          (3)   The maximum transient voltage let-through of the                                            104.6 mm
           protector throughout the test (±10%), line to line &
           line to earth, both polarities. Response time < 10 ns           106.5 mm
          (4)   Test to IEC 61000-4-5:2006, ITU-T (formerly
           CCITT) K.20, K.21 and K.45,Telcordia
           GR-1089-CORE, Issue 2:2002, ANSI TIA/EIA/        7 mm    2  S  1          1  S  2  E
           IS-968-A:2002 (formerly FCC Part 68)