Page 570 - Din prodcuts 2020
P. 570

5/126            ELECTRICAL INSTALL ATION SOLUTIONS FOR BUILDINGS   2CHC 420 001 C0201




          —
          Protection and safety
          Data & signal protection
          OVR TN, TNQ & SL TN Series






  5






                                            Combined Category D, C, B tested protector (to BS EN 61643) specifically
                                            designed for telecommunications applications in accordance with Telcordia
                                            and ANSI standards (see Application Note OVR AN005). For use at boundaries
                                            up to LPZ 0 to protect against flashover (typically the service entrance location)
                                            through to LPZ 3. Available as standard OVR TN format, or compact
                                            OVR TNQ and Slim Line OVR SL TN versions for installations where a high
                                            number of lines require protection.

          Features & benefits
          •  Very low let-through voltage (enhanced protection to    •  OVR TN can be flat mounted on base or side
           IEC/BS EN 62305) between all lines - Full Mode protection  •  OVR TN and OVR TNQ have colour coded terminals for
          •  Full Mode design capable of handling partial lightning   quick and easy installation check
           currents as well as allowing continual operation of   •  OVR SL TN has ultra slim 7 mm width ideal for compact
           protected equipment                                 protection of large numbers of lines (e.g. process control
          •  Repeated protection in lightning intense environments  installations)
          •  20 MHz bandwidth greatly exceeds VDSL2+          •  OVR SL TN includes two stage removable protection
           (50Mbps ~ 7MHz) maximum speeds                      module with simple quick release mechanism allowing
          •  Low in-line resistance minimizes reductions in signal   partial removal for easy line commissioning and
           strength                                            maintenance as well as full removal for protection
          •  Built-in DIN rail foot for simple mounting to top hat DIN rails  replacement
          •  Convenient earthing through DIN foot and/or earth   •  OVR SL TN includes optional LED status indication
           terminal                                            (add L suffix to part number - i.e. OVR SL TNL)


          Application                                         Accessories
                                                              Replacement module for OVR SL TN:  If protectors cannot be incorporated
          Connect in series with the signal line either near where it   OVR SLTN/M      within an existing panel or enclosure,
          enters or leaves the building or close to the equipment being   Standard module replacement  OVR WBX enclosures are available
                                                                                        for up to 4, 8, 16 or 32 protectors
          protected ensuring it is very close to the system’s earth star   Combined Mounting/Earthing kits for    and their associated OVR CME kit.
          point. Install protectors either within an existing   OVR RS485:
                                                              OVR CME 4 For up to 4 x OVR TN  Weatherproof enclosure:
          cabinet/cubicle or in a separate enclosure.         OVR CME 8 For up to 8 x OVR TN  OVR WBX SLQ (OVR SLTN and OVR TNQ)
                                                              OVR CME 16 For up to 16 x OVR TN
                                                              OVR CME 32 For up to 32 x OVR TN



         OVR TN installed in series           OVR SL TN installed in series         OVR TNQ installed in series (in-line)
         DIRTY                                                      CLEAN  LINE                                                       CLEAN  DIRTY                                                   CLEAN
                                                 LINE      Lightning Barrier  CLEAN
                                                           Nominal voltage  30V
                                                           Max working voltage, U c 36.7V
                          OVR TN               1           Current rating  750mA 1.0Ω 20kA 63V  3
                                                           In-line resistance
                                                           Max surge current
                     OVR TN
                                                           Let-through voltage, U p
         From                  To              S           Furse Wilford Road,  S                OVR TNQ
                                                           Nottingham,
                                                           NG2 1EB, UK
         line                  equipment
                     Earth                     2                         4
                                                                                     From                To
                                                                                     line       Earth    equipment
                                                                 To equipment
                                              From line         To equipment
                                               From line
                                                          Earth
                                                          Earth
          NOTE: The OVR KT Series is also available for telecommunications application using LSA-PLUS disconnection modules.