Page 70 - SACE Tmax XT - Catalogue
P. 70

3/36             SACE TMAX XT LOW VOLTAGE MOLDED CASE CIRCUIT-BREAKERS



          —

          Ekip Touch/Hi-Touch


          Protection functions










          ABB Code         ANSI Code        Function         Ekip Touch LSI   Ekip Touch LSIG  Ekip Touch                        Ekip Touch       Ekip Hi-Touch LSI  Ekip Hi-Touch LSIG  Ekip M Touch LRIU  Ekip G Touch LSIG  Ekip G Hi-Touch LSIG
                                                                                               Measuring LSI                     Measuring LSIG
          Frequency Protection package
          UF               81L              Underfrequency                                                                                        ●                ●                ●                ●                ●
          OF               81H              Overfrequency                                                                                         ●                ●                ●                ●                ●
          UF2              81L              2nd Underfrequency                                                                                    ●                ●                ●                                 ●
          OF2              81H              2nd Overfrequency                                                                                     ●                ●                ●                                 ●
          Power Protection package
          RP               32R              Reverse active power                                                                                  ●                ●                ●                ●                ●
          Cos ϕ            78               Power Factor                                                                                          ●                ●                ●                ●                ●
          D                67               Directional overcurrent                                                                               ●                ●                ●                                 ●
          RQ               40/32R           Loss of field or reverse                                                                                                                                 ●                ●
                                            reactive power
          OQ               320F             Reactive overpower                                                                                                                                       ●                ●
          OP               320F             Active overpower                                                                                                                                         ●                ●
          UP               32LF             Active underpower                                                                                                                                        ●                ●
          ROCOF Protection package
          ROCOF            81R              Rate of change of                                                                                                                                                         ●
                                            frequency
          Adaptive Protection package
          Set A-B                           Dual Setting                                                                                          ●                ●                ●                                 ●
          Motor Protection
          L                                 Motor protection                                                                                                                        ●
                                            overload
          R                51LR             Rotor bloackage                                                                                                                         ●
          U                46               Phase lackand/or                                                                                                                        ●
                                            unbalance
          Uc               37               Undercurrent                                                                                                                            ●
          Protection with additional modules
          SC               25               Synchrocheck     ●                ●                ●                                 ●                ●                ●                ●                ●                ●
          Ekip CI                           Motor contactor                                                                                                                         ●
                                            interface protection
          PTC                               PTC for temperature                                                                                                                     ●
          G ext            50G TD/86/51G    Earth fault                       ●  (1)                                             ●  (1)                            ●  (1)                            ●  (1)           ●  (1)
          Rc               64 50N TD 87N    Residual current /                ●  (1)                                             ●  (1)                            ●  (1)           ●  (1)           ●  (1)           ●  (1)
                                            Differential ground
                                            fault
          ●  Available
             Available as software package to be ordered via ABB Ability Marketplace TM  or during the circuit-breaker ordering phase. To add this function, the Measuring package
                must be installed first.
          Note:
          1) Available with additional module for XT7 and XT7 M only

          When an Ekip Touch LSI or LSIG trip unit is upgraded with one of the following packages:
          •  Voltage Protection
          •  Voltage Protection Advanced
          •  Frequency Protection
          •  Power Protection
          •  ROCOF Protection
          it is mandatory to add first the Measuring package described on the following pages.