                                            Combined Category D, C, B tested protector (to BS EN 61643) suitable for 3-wire
                                            signalling applications which require either a lower in-line resistance, an
                                            increased current and/or higher bandwidth. Also suitable for DC power
                                            applications less than 0.5 Amps. Available for working voltages of up to 6, 15,
                                            30, 50 and 110 Volts. For use at boundaries up to LPZ 0 to protect against
                                            flashover (typically the service entrance location) through to LPZ 3 to protect
                                            sensitive electronic equipment.

          Features & benefits
          •  Very low let-through voltage (enhanced protection to    •  High (500 mA) maximum running current
           IEC/BS EN 62305) between all lines - Full Mode protection  •  High bandwidth enables higher frequency (high traffic or
          •  Full Mode design capable of handling partial lightning   bit rate) data communications
           currents as well as allowing continual operation of   •  Strong, flame retardant, polycarbonate housing
           protected equipment                                •  Built-in innovative DIN rail foot with locking feature for
          •  Repeated protection in lightning intense environments  simple positioning and clip-on mounting to top hat DIN
          •  Ultra slim 7 mm width ideal for compact protection of   rails
                                                                    2
           large numbers of lines (e.g. process control installations)  •  4 mm  terminals allow for larger cross section wiring,
          •  Two stage removable protection module with simple quick   stranded wires terminated with ferrules or fitting two
           release mechanism allowing partial removal for easy line   wires into a single terminal
           commissioning and maintenance as well as full removal for   •  Convenient earthing through DIN foot and/or earth
           protection replacement                              terminal
          •  Very low (1 Ω) in-line resistance allows resistance critical
           applications (e.g. alarm loops) to be protected

          Application                                         Installation
          Use these protectors for 3-wire systems where installation   Connect in series with the data communication or signal line
          space is at a premium and large numbers of lines require   either near where it enters or leaves the building or close to
          protection (e.g. process control, high speed digital   the equipment being protected (e.g. within its control
          communication equipment or systems with long signal   panel). Either way, it must be very close to the system’s
          lines).                                             earth star point. Install protectors either within an existing
                                                              cabinet/cubicle or in a separate enclosure.




                                                                    LINE                                                      CLEAN
                                                                                          CLEAN
                                                                       LINE
          Accessories                                                            Lightning Barrier
                                                                                 Nominal voltage  30V
                                                                                 Max working voltage, U c 36.7V 750mA
                                                                                 Current rating
          Replacement modules:      OVR WBX SLQ                      1           In-line resistance  20kA 1.0Ω 63V  3
                                                                                 Max surge current
                                                                                 Let-through voltage, U p
          OVR SLXX/3W/M                                                          Furse Wilford Road,
                                                                                 Nottingham,
                                                                                 NG2 1EB, UK
          Standard module replacement                                S                         S
          where XX is voltage rating                                 2                         4
          (06, 15, 30, 50 or 110)
          OVR SL/3W/B
          Base replacement
          Weatherproof enclosure:                                    From line        To equipment
                                                                                       To equipment
                                                                     From line
                                                                                Earth
                                                                                 Earth
          NOTE: The OVR SL ‘Slim Line’ Series is also available for protection of 2-wire systems up to 110 V, RS 485, RTD and telecommunication applications
          (OVR SL Series, OVR SL RS485, OVR SL RTD and OVR SL TN). The OVR SL X Series has approvals for use in hazardous areas.
   553   554   555   556   557   558   559   560   561   562   563