Page 557 - Din prodcuts 2020
P. 557

5/113




          —
          Protection and safety
          Data & signal protection
          OVR H Series


          OVR H Series - Technical specification
          Electrical specification      OVR 06H        OVR 15H       OVR 30H       OVR 50H        OVR 110H
          ABB order code                7TCA085400R0355 7TCA085400R0357 7TCA085400R0358 7TCA085400R0359 7TCA085400R0356  5
          Nominal voltage  (1)          6 V            15 V          30 V          50 V           110 V
          Maximum working voltage Uc (RMS/DC)  (2)  5 V/7.79 V   11 V/16.7 V   25 V/36.7 V   40 V/56.7 V   93 V/132 V
          Current rating (signal)       4 A
          In-line resistance (per line ±10%)  0.05 Ω
          Bandwidth (-3 dB 50 Ω system)  160 KHz       140 KHz       130 KHz       120 KHz        120 KHz
          Transient specification       OVR 06H        OVR 15H       OVR 30H       OVR 50H        OVR 110H
          Let-through voltage
          (all conductors)   Up
                     (3)
          C2 test 4 kV 1.2/50 μs, 2 kA 8/20 μs to    12.0 V   27.5 V   46.0 V      67.0 V         150 V
          BS EN/EN/IEC 61643-21
          C1 test 1 kV, 1.2/50 μs, 0.5 kA 8/20 μs to   11.0 V   26.5 V   45.0 V    66.5 V         145 V
          BS EN/EN/IEC 61643-21
          B2 test 4 kV 10/700 μs to BS EN/EN/IEC   10.5 V   25.5 V   43.5 V        65.0 V         140 V
          61643-21
          5 kV, 10/700 μs  (4)          10.8 V         26.2 V        44.3 V        65.8 V         145 V
          Maximum surge current
          D1 test 10/350 μs   – Per signal wire  2.5 kA
          to BS EN/EN/IEC   – Per pair  5 kA
          61643-21
          8/20 μs to ITU-T   – Per signal wire  10 kA
          K.45:2003, IEEE   – Per pair  20 kA
          C62.41.2:2002
          Mechanical specification      OVR 06E        OVR 15E       OVR 30E       OVR 50E        OVR 110E
          Temperature range             -40 to +80 °C
          Connection type               Screw terminal - maximum torque 0.5 Nm
          Conductor size (stranded)     2.5 mm 2
          Earth connection              M6 stud - maximum torque 0.5 Nm
          Case material                 FR Polymer UL-94 V-0
          Weight         – Unit         0.08 kg
                         – Packaged (per 10)  0.85 kg
          Dimensions                    See diagram below






                                                                                                             54 mm
                                                                                 38 mm

                                                                                               105 mm
                                                                                              M4 clearance

                                                                                               120 mm
                                                                                 19 mm
                                                                                               109 mm
                                                                                              M4 clearance
          (1)   Nominal voltage (RMS/DC or AC peak)
           measured at < 10 μA (OVR 15H, OVR 30H,
           OVR 50H, OVR 110H) and < 200 μA (OVR 06H)
          (2)   Maximum working voltage (RMS/DC or AC peak)
           measured at < 5 mA leakage (OVR 15H, OVR 30H,
           OVR 50H, OVR 110H) and < 10 mA (OVR 06H)
          (3)   The maximum transient voltage let-through of the
           protector throughout the test (±10%), line to line &
           line to earth, both polarities. Response time < 10 ns
          (4)   Test to IEC 61000-4-5:2006, ITU-T (formerly
           CCITT) K.20, K.21 and K.45,Telcordia
           GR-1089-CORE, Issue 2:2002, ANSI TIA/EIA/
           IS-968-A:2002 (formerly FCC Part 68)
   552   553   554   555   556   557   558   559   560   561   562