          Performances at different ambient temperatures




          Max. operating current depending on the ambient temperature of S800U
          U-K,   Ambient temperature T (°C)
          Z,
          UCZ
          I  (A)  –25  –20  –15  –10   –5    0    5    10   15    20   25    30   35   40    45   50    55   60
          e
          10    11,8  11,7  11,5  11,3  11,1  10,9  10,7  10,6  10,4  10,2  10  9,8  9,6  10  9,3  9,1  8,9  8,7
          13    15,4  15,1  14,9  14,7  14,4  14,2  14  13,7  13,5  13,2  13  12,8  12,5  13  12  11,8  11,6  11,3
          16     19  18,5  18,5  18    18  17,5   17   17  16,5  16,5  16  15,5  15,5   16   15  14,5   14   14
          20    23,5  23,5  23  22,5   22   22  21,5   21  20,5  20,5  20  19,5  19,5   20  18,5  18    18  17,5
          25    29,5  29  28,5   28    28  27,5  27   26,5  26  25,5   25  24,5   24    25   23  22,5   22   22
          32     38  37,5  36,5  36  35,5   35  34,5   34   33  32,5   32  31,5   31    32  29,5  29   28,5  28
          40    47,5  46,5  46   45  44,5  43,5  43    42  41,5  40,5  40  39,5  38,5  40    37  36,5  35,5  35
          50     59  58,5  57,5  56,5  55,5  54,5  53,5  53  52   51   50    49   48   50   46,5  45,5  44,5  43,5
          63    74,5  73,5  72   71    70   69  67,5  66,5  65,5  64   63    62  60,5   63  58,5  57    56   55
          80     95   93    92   90    89   87   86    84   83    82   84    79   77    76   74   73    71   70
          100   118   117  115  113   111  109   107  106  104   102  100    98   96    95   93   91    89   87


          Max. operating current depending on the ambient temperature of S804U - PVSP5, - PVS5
          - PVSP5, - PVS5 Ambient temperature T (°C)
          I  (A)      –25  –20  –15  –10   –5   0    5    10   15   20   25   30   35   40   45   50   55   60
          n
          5           6,50  6,40  6,30  6,20  6,10  6,00  5,90  5,80  5,70  5,60  5,50  5,40  5,30  5,2  5,10  5,00  4,90  4,80
          Influence of mounting distances between the devices
          Multiply the rated current referring to your max. occurrent temperature with the factor of “influence of mounting distances”.
          Example: 2 x S802B-B125 at T = 40 °C with distance
          I  = 120.4 A x 92.1 % = 110.9 A
          n
           100.0%



           Percentage of operating current I
  90.0%                                               6 A to 32 A
            95.0%





                                                                                                   40 A to 63 A
                                                                                                   80 A to 125 A

            85.0%



            80.0%
                 0             5             10             15            20             25
                                         Influence of mounting distances [mm]
          Further influencing factors, which can lead to a reduction of the maximum operating current, are:
          - Shortening the cable lenght compared to IEC 60947-1/2
          - Reducing the cable cross section compared to IEC 60947-1/2
          - Accumulation of cables