Page 574 - Din prodcuts 2020
P. 574

5/130            ELECTRICAL INSTALL ATION SOLUTIONS FOR BUILDINGS   2CHC 420 001 C0201




          —
          Protection and safety
          Data & signal protection
          OVR RS485, RS485Q & SL RS485 Series






  5





                                            Combined Category D, C, B tested protector (to BS EN 61643) specifically
                                            designed for RS 485 and Fieldbus applications, such as Profibus DP.
                                            For use at boundaries up to LPZ 0 to protect against flashover (typically the
                                            service entrance location) through to LPZ 3. Available as standard OVR RS485
                                            format, or compact OVR RS485Q and Slim Line OVR SL RS485 versions for
                                            installations where a high number of lines require protection.


          Features & benefits
          •  Very low let-through voltage (enhanced protection to    •  OVR RS485 can be flat mounted on base or side
           IEC/BS EN 62305) between all lines - Full Mode protection  •  OVR RS485 and OVR RS485Q have colour coded terminals
          •  Full Mode design capable of handling partial lightning   for quick and easy installation check
           currents as well as allowing continual operation of   •  OVR SL RS485 has ultra slim 7 mm width ideal for compact
           protected equipment                                 protection of large numbers of lines
          •  Repeated protection in lightning intense environments  (e.g. process control installations)
          •  45 MHz bandwidth greatly exceeds 12 Mbps maximum   •  OVR SL RS485 includes two stage removable protection
           speeds                                              module with simple quick release mechanism allowing
          •  Low in-line resistance minimizes reductions in signal   partial removal for easy line commissioning and
           strength                                            maintenance as well as full removal for protection
          •  Suitable for earthed or isolated screen systems   replacement
          •  Built-in DIN rail foot for simple mounting to top hat DIN rails  •  OVR SL RS485 includes optional LED status indication
          •  Convenient earthing through DIN foot and/or earth   •  Add L suffix to part number - i.e. OVR SL RS485L
           terminal
                                                              Accessories
          Application                                         Replacement module for OVR SL RS485:  If protectors cannot be incorporated
          Connect in series with the signal line either near where it   OVR SLRS485/M    within an existing panel or enclosure,
          enters or leaves the building or close to the equipment being   Standard module replacement   OVR WBX enclosures are available
                                                              OVR SLRS485/B
                                                                                        for up to 4, 8, 16 or 32 protectors
          protected ensuring it is very close to the system’s earth star   Base replacement  and their associated OVR CME kit.
          point. Install protectors either within an existing   Combined Mounting/Earthing kits for    Weatherproof enclosure:
          cabinet/cubicle or in a separate enclosure.         OVR RS485:                OVR WBX SLQ (OVR SL RS485 and
                                                              OVR CME 4 For up to 4 x OVR RS485  OVR RS485Q)
                                                              OVR CME 8 For up to 8 x OVR RS485
                                                              OVR CME 16 For up to 16 x OVR RS485
                                                              OVR CME 32 For up to 32 x OVR RS485
          OVR RS485 installed in series      OVR SL RS485 installed in series      OVR RS485Q installed in series (in-line)

          DIRTY                                                      CLEAN  LINE                                                       CLEAN  DIRTY                                                   CLEAN
                                                LINE      Lightning Barrier  CLEAN
                                                          Nominal voltage  30V
                                                          Max working voltage, U c 36.7V
                                                          Current rating  750mA 1.0Ω
                                                          In-line resistance
                                              1           Max surge current  20kA 63V  3
                                                          Let-through voltage, U p
          From                 To             S            Furse Wilford Road,  S
                                                           Nottingham,
                                                           NG2 1EB, UK
          line                 equipment
                      Earth                   2                          4
                                                                                   From                 To
                                                                                   line       Earth     equipment
                                                                To equipment
                                              From line         To equipment
                                              From line
                                                          Earth
                                                          Earth
          NOTE: The OVR SL ‘Slim Line’ Series is also available for protection of 3-wire and RTD applications (OVR SL/3W & OVR SL RTD).
          The OVR SL X Series has approvals for use in hazardous areas.
   569   570   571   572   573   574   575   576   577   578   579